CoChat

Analysis for Perfluorocarboxylic Acids/Anions in Surface Waters and Precipitation Using GC−MS and Analysis of PFOA from Large-Volume Samples

Scott, Brian F., Moody, Cheryl A., Spencer, Christine, Small, Jeffrey M., Muir, Derek C. G., Mabury, Scott A. · 2006 · Environmental Science & Technology
Cited by 147

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The presence of perfluorocarboxylates (PFCAs) in the environment is of increasing concern, following the discovery of perfluoroalkyl acids (PFAs) in wildlife and human samples. Here we report a method forthe determination of (C2-C9) PFCAs by preparing the 2,4-difluoroanilides of the acids and analyzing by using GC-MS. Detector response was linear over the range 0.1 -1000 pg of each perfluoroalkyl anilide. A complete suite of PFCAs can be analyzed in an individual sample with the PFCAs detected at levels similar to or lower than those determined by other methods. For a comparison between the present method and the more common LC-MS/MS method, 10 replicates of a sewage treatment plant discharge were analyzed for perfluoro-octanoic acid (PFOA) using both methods. Results were nearly identical with low standard deviation (GC-MS 30.9 +/- 1.88 ng/L; while the LC-MS/MS 34.7 +/- 3.05 ng/L). PFCA concentrations for water samples collected from depth profiles in mid-Lake Ontario were analyzed by GC-MS with most PFCAs (C2-C8) present above the detection limit (0.5 ng/L). Major PFCAs were trifluoroacetate (TFA) (100 ng/L) and perfluorobutanoate (PFBA) (> 5 ng/L). Results for PFOA (2.5 ng/L) were in good agreement with recent analyses by LC-MS/MS. PFCAs were also detected in the precipitation samples at concentrations lower than those of the samples from the lake profiles or sewage treatment plants (STPs) effluent. Since PFOA levels may be less than the lower detection limit (<0.5 ng/L) in 1 L samples, a method for large volumes using XAD-7 resin was developed that allows detection to 0.01 ng/L. This method was applied to Lake Superior samples which produced good agreement for C6-C9 PFCAs between regular analysis (GC-MS) and the XAD-7 followed by GC-MS analysis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/es061131o

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Scott, B. F., Moody, C. A., Spencer, C., Small, J. M., Muir, D. C. G., & Mabury, S. A.
Venue
Environmental Science & Technology
Published
2006-09-14
Volume
40
Issue
20
Pages
6405-6410
ISSN
  • 0013-936X (ISSN-L)
  • 1520-5851
OpenAlex
W2058335098
Cited by
147
References
3
FWCI
7.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.