Volatile Organic Compounds in Small- and Medium-Sized Commercial Buildings in California
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
While small- and medium-sized commercial buildings (SMCBs) make up 96% of the commercial buildings in the U.S., serving a large variety of uses, little information is available on indoor air quality (IAQ) in SMCBs. This study investigated 37 SMCBs distributed across different sizes, ages, uses, and regions of California. We report indoor concentrations and whole building emission rates of a suite of 30 VOCs and aldehydes in these buildings. There was a considerable range in the concentrations for each of the contaminants, especially for formaldehyde, acetaldehyde, decamethylcyclopentasiloxane, d-limonene, 2-butoxyethanol, toluene, 2,2,4-trimethylpentanediol diisobutyrate, and diethylphthalate. The cause of higher concentrations in some building categories generally corresponded to expected sources, for example, chloroform was higher in restaurants and grocery stores, and formaldehyde was higher in retail stores and offices. Factor analysis suggests sources in SMCBs include automobile/traffic, cleaning products, occupant sources, wood products/coating, and plasticizers. The comparison to health guidelines showed that formaldehyde concentrations were above the chronic RELs required by the OEHHA (9 μg/m3) in 86% of the buildings. Data collected in this study begins to fill the knowledge gap for IAQ in SMCBs and helps us understand the indoor sources of VOCs to further improve indoor air quality in SMCBs.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In offices in California, levels of individual VOCs ranged from non-detect to over 1000 μg/m3 [48, 49].”
From Occupational exposure and health risks of volatile organic compounds of hotel housekeepers: Field measurements of exposure and health risks (2021) · cites this paper as [49]
Citations
Cites
KLEPEIS, N. E., NELSON, W. C., OTT, W. R., ROBINSON, J. P., TSANG, A. M., SWITZER, P., BEHAR, J. V., HERN, S. C., & ENGELMANN, W. H. (2001) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500165 · Cited by 4,803
Cleaning products and air fresheners: exposure to primary and secondary air pollutants
Nazaroff, W. W., & Weschler, C. J. (2004) · Atmospheric Environment · doi:10.1016/j.atmosenv.2004.02.040 · Cited by 846
Aldehyde Sources, Metabolism, Molecular Toxicity Mechanisms, and Possible Effects on Human Health
O'Brien, P. J., Siraki, A. G., & Shangari, N. (2005) · Critical Reviews in Toxicology · doi:10.1080/10408440591002183 · Cited by 738
Atmospheric chemistry. Fundamentals and experimental techniques
Hewitt, C. N. (1987) · Endeavour · doi:10.1016/0160-9327(87)90267-5 · Cited by 605
Emission Rates of Formaldehyde from Materials and Consumer Products Found in California Homes
Kelly, T. J., Smith, D. L., & Satola, J. (1999) · Environmental Science & Technology · doi:10.1021/es980592+ · Cited by 201
Ozone Interactions with Carpet: Secondary Emissions of Aldehydes
Morrison, G. C., & Nazaroff, W. W. (2002) · Environmental Science & Technology · doi:10.1021/es0113089 · Cited by 185
Daisey, J. M., Hodgson, A. T., Fisk, W. J., Mendell, M. J., & Brinke, J. T. (1994) · Atmospheric Environment · doi:10.1016/1352-2310(94)00200-5 · Cited by 153
Proceedings of Healthy Buildings 2000
Sigsgaard, T., Jensen, H., Nichum, E., Gravesen, S., Larsen, L. J., & Hansen, M. (2000) · Cited by 145
Sax, S. N., Bennett, D. H., Chillrud, S. N., Kinney, P. L., & Spengler, J. D. (2004) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500364 · Cited by 102
Self-citationMeasured Concentrations of VOCs in Several Non-Residential Microenvironments in the United States
Loh, M. M., Houseman, E. A., Gray, G. M., Levy, J. I., Spengler, J. D., & Bennett, D. H. (2006) · Environmental Science & Technology · doi:10.1021/es060197g · Cited by 71
Self-citation
Research works printed but not linked: 7
- Brown, 1999, Chamber assessment of formaldehyde and VOC emissions from wood-based panels, Indoor AirInt. J. Indoor Air Qual. Clim., 9, 209
- Lee, 2001, High Performance Commercial Building Systems, Report on metrics appropriate for small commercial customers and report on selection of case study sites
- Shields, 1996, Comparisons among VOCs measured in three types of US commercial buildings with different occupant densities, Indoor AirInt. J. Indoor Air Qual. Clim., 6, 2
- Hodgson, 2003, Volatile organic compounds in indoor air: A review of concentrations measured in North America since 1990
- Woolfenden, 1997, Compendium Method TO-17: Determination of volatile organic compounds in ambient air using active sampling onto sorbent tubes
- Willbury, 1999, Compendium Method TO-11A: Determination of formaldehyde in ambient air using absorbent cartridge followed by high performance liquid chromatography (HPLC) [active sampling methodology]
- EHE, 2002, A Screening-Level Ranking of Organic Chemicals and Metals Found in Indoor Air
Cited by
Volatile chemical products emerging as largest petrochemical source of urban organic emissions
McDonald, B. C., de Gouw, J. A., Gilman, J. B., Jathar, S. H., Akherati, A., Cappa, C. D., Jimenez, J. L., Lee-Taylor, J., Hayes, P. L., McKeen, S. A., et al. (2018) · Science · doi:10.1126/science.aaq0524 · Cited by 1,373
Environmental Chemistry of Organosiloxanes
Rücker, C., & Kümmerer, K. (2015) · Chemical Reviews · doi:10.1021/cr500319v · Cited by 348
Indoor ozone: Concentrations and influencing factors
Nazaroff, W. W., & Weschler, C. J. (2022) · Indoor Air · doi:10.1111/ina.12942 · Cited by 163
Indoor environmental quality benefits of apartment energy retrofits
Noris, F., Adamkiewicz, G., Delp, W. W., Hotchi, T., Russell, M., Singer, B. C., Spears, M., Vermeer, K., & Fisk, W. J. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.07.003 · Cited by 134
Towards practical indoor air phytoremediation: A review
Pettit, T. J., Irga, P. J., & Torpy, F. R. (2018) · Chemosphere · doi:10.1016/j.chemosphere.2018.06.048 · Cited by 136
Metadata
- Authors
- Wu, X. (., Apte, M. G., Maddalena, R., & Bennett, D. H.
- Affiliations
- University of California, Davis (US)
- Lawrence Berkeley National Laboratory (US)
- Corresponding author
- Bennett, Deborah H.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-09-02
- Volume
- 45
- Issue
- 20
- Pages
- 9075-9083
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2324976055
- Cited by
- 97
- References
- 16
- Citations by year
- 2026: 3 · 2025: 4 · 2024: 3 · 2023: 5 · 2022: 4 · 2021: 4 · 2020: 7 · 2019: 5 · 2018: 5 · 2017: 4 · 2016: 10 · 2015: 12 · 2014: 11 · 2013: 16 · 2012: 4
- FWCI
- 7.17
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Environmental Science & Technology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Physical Sciences › Earth and Planetary Sciences › Atmospheric Science › Atmospheric chemistry and aerosols
- Keywords
- volatile organic compounds, indoor air quality, formaldehyde, aldehydes, indoor air quality guidelines, source apportionment, vehicle emissions, cleaning agents, wood products, plasticizers, California
- MeSH terms
- Aldehydes, Environmental Monitoring, Air Pollution, Indoor, Volatile Organic Compounds
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.