The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Carbon Nanotube Membrane Stack for Flow-through Sequential Regenerative Electro-Fenton
Abstract
Electro-Fenton is a promising advanced oxidation process for water treatment consisting a series redox reactions. Here, we design and examine an electrochemical filter for sequential electro-Fenton reactions to optimize the treatment process. The carbon nanotube (CNT) membrane stack (thickness ∼ 200 μm) used here consisted of 1) a CNT network cathode for O2 reduction to H2O2, 2) a CNT-COOFe(2+) cathode to chemical reduction H2O2 to (•)OH and HO(-) and to regenerate Fe(2+) in situ, 3) a porous PVDF or PTFE insulating separator, and 4) a CNT filter anode for remaining intermediate oxidation intermediates. The sequential electro-Fenton was compared to individual electrochemical and Fenton process using oxalate, a persistent organic, as a target molecule. Synergism is observed during the sequential electro-Fenton process. For example, when [DO]in = 38 ± 1 mg L(-1), J = 1.6 mL min(-1), neutral pH, and Ecell = 2.89 V, the sequential electro-Fenton oxidation rate was 206.8 ± 6.3 mgC m(-2) h(-1), which is 4-fold greater than the sum of the individual electrochemistry (16.4 ± 3.2 mgC m(-2) h(-1)) and Fenton (33.3 ± 1.3 mgC m(-2) h(-1)) reaction fluxes, and the energy consumption was 45.8 kWh kgTOC(-1). The sequential electro-Fenton was also challenged with the refractory trifluoroacetic acid (TFA) and trichloroacetic acid (TCA), and they can be transferred at a removal rate of 11.3 ± 1.2 and 21.8 ± 1.9 mmol m(-2) h(-1), respectively, with different transformation mechanisms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pignatello, J. J., Oliveros, E., & MacKay, A. (2006) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643380500326564 · Cited by 4,133
Electro-Fenton Process and Related Electrochemical Technologies Based on Fenton’s Reaction Chemistry
Brillas, E., Sirés, I., & Oturan, M. A. (2009) · Chemical Reviews · doi:10.1021/cr900136g · Cited by 3,437
LXXIII.—Oxidation of tartaric acid in presence of iron
Fenton, H. J. H. (1894) · J. Chem. Soc., Trans. · doi:10.1039/ct8946500899 · Cited by 3,179
Cited by
Kofuji, Y., Isobe, Y., Shiraishi, Y., Sakamoto, H., Tanaka, S., Ichikawa, S., & Hirai, T. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.6b05806 · Cited by 587
Current advances and trends in electro-Fenton process using heterogeneous catalysts – A review
Poza-Nogueiras, V., Rosales, E., Pazos, M., & Sanromán, M. Á. (2018) · Chemosphere · doi:10.1016/j.chemosphere.2018.03.002 · Cited by 375
Su, P., Zhou, M., Lu, X., Yang, W., Ren, G., & Cai, J. (2019) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2018.12.075 · Cited by 313
Jiang, W.-L., Xia, X., Han, J.-L., Ding, Y.-C., Haider, M. R., & Wang, A.-J. (2018) · Environmental Science & Technology · doi:10.1021/acs.est.8b01894 · Cited by 293
Electro-oxidation of organic pollutants by reactive electrochemical membranes
Trellu, C., Chaplin, B. P., Coetsier, C., Esmilaire, R., Cerneaux, S., Causserand, C., & Cretin, M. (2018) · Chemosphere · doi:10.1016/j.chemosphere.2018.05.026 · Cited by 282
Metadata
- Authors
- Gao, G., Zhang, Q., Hao, Z., & Vecitis, C. D.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-01-28
- Volume
- 49
- Issue
- 4
- Pages
- 2375-2383
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2332392048
- Cited by
- 251
- References
- 3
- FWCI
- 14.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Carbon Nanotube Membrane Stack for Flow-through Sequential Regenerative Electro-Fenton. https://app.cochat.ai/papers/10.1021/es505679e
- The paper
- Gao, G., Zhang, Q., Hao, Z., & Vecitis, C. D. (2015). Carbon Nanotube Membrane Stack for Flow-through Sequential Regenerative Electro-Fenton. Environmental Science & Technology. https://doi.org/10.1021/es505679e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.