The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Room-Temperature Ionic Liquid−Amine Solutions: Tunable Solvents for Efficient and Reversible Capture of CO2
Abstract
Solutions of room-temperature ionic liquids (RTILs) and commercially available amines were found to be effective for the capture of CO 2 as carbamate salts. RTIL solutions containing 50 mol % (16% v/v) monoethanolamine (MEA) are capable of rapid and reversible capture of 1 mol of CO 2 per 2 moles MEA to give an insoluble MEA−carbamate precipitate that helps to drive the capture reaction (as opposed to aqueous amine systems). Diethanolamine (DEA) can also be used in the same manner for CO 2 capture in RTILs containing a pendant hydroxyl group. The captured CO 2 in the resulting RTIL−carbamate salt mixtures can be readily released by either heating and/or subjecting them to reduced pressure. Using this unprecedented and industrially attractive mixing approach, the desirable properties of RTILs (i.e., nonvolatility, enhanced CO 2 solubility, lower heat capacities) can be combined with the performance of amines for CO 2 capture without the use of specially designed, functionalized “task-specific” ionic liquids. By mixing RTILs with commercial amines, reactive solvents with a wide range of amine loading levels can be tailored to capture CO 2 in a variety of conditions and processes. These RTIL−amine solutions behave similarly to their water-based counterparts but may offer many advantages, including increased energy efficiency, compared to current aqueous amine technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2007) · Wiley eBooks · doi:10.1002/9783527621194 · Cited by 2,768
CO2 Capture by a Task-Specific Ionic Liquid
Bates, E. D., Mayton, R. D., Ntai, I., & Davis, J. H. (2002) · Journal of the American Chemical Society · doi:10.1021/ja017593d · Cited by 2,270
Han, X., & Armstrong, D. W. (2007) · Accounts of Chemical Research · doi:10.1021/ar700044y · Cited by 1,024
Thermochemistry of ionic liquid heat-transfer fluids
Valkenburg, M. E. V., Vaughn, R. L., Williams, M., & Wilkes, J. S. (2005) · Thermochimica Acta · doi:10.1016/j.tca.2004.11.013 · Cited by 595
Gas treating with chemical solvents
Fair, J. (1984) · Chemical Engineering Science · doi:10.1016/0009-2509(84)80095-0 · Cited by 557
Smiglak, M., Metlen, A., & Rogers, R. D. (2007) · Accounts of Chemical Research · doi:10.1021/ar7001304 · Cited by 496
Solubility of CO2in Room Temperature Ionic Liquid [hmim][Tf2N]
Shiflett, M. B., & Yokozeki, A. (2007) · The Journal of Physical Chemistry B · doi:10.1021/jp067627+ · Cited by 258
Bulk-Fluid Solubility and Membrane Feasibility of Rmim-Based Room-Temperature Ionic Liquids
Camper, D., Bara, J., Koval, C., & Noble, R. (2006) · Industrial & Engineering Chemistry Research · doi:10.1021/ie060177n · Cited by 248
Self-citationWidegren, J. A., & Magee, J. W. (2007) · Journal of Chemical & Engineering Data · doi:10.1021/je700329a · Cited by 235
Heat capacities of ionic liquids and their heats of solution in molecular liquids
Waliszewski, D., Stępniak, I., Piekarski, H., & Lewandowski, A. (2005) · Thermochimica Acta · doi:10.1016/j.tca.2005.03.001 · Cited by 165
Modeling of Blast Furnace CO2 Capture Using Amine Absorbents
Tobiesen, F. A., Svendsen, H. F., & Mejdell, T. (2007) · Industrial & Engineering Chemistry Research · doi:10.1021/ie061556j · Cited by 97
Cited by
Carbon capture and storage (CCS): the way forward
Bui, M., Adjiman, C. S., Bardow, A., Anthony, E. J., Boston, A., Brown, S., Fennell, P. S., Fuss, S., Galindo, A., Hackett, L. A., et al. (2018) · Energy & Environmental Science · doi:10.1039/c7ee02342a · Cited by 4,374
A Review of CO2 Capture by Absorption and Adsorption
Yu, C.-H., Huang, C.-H., & Tan, C.-S. (2012) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2012.05.0132 · Cited by 1,730
An overview of CO2 capture technologies
MacDowell, N., Florin, N., Buchard, A., Hallett, J., Galindo, A., Jackson, G., Adjiman, C. S., Williams, C. K., Shah, N., & Fennell, P. (2010) · Energy & Environmental Science · doi:10.1039/c004106h · Cited by 1,636
State-of-the-Art of CO2Capture with Ionic Liquids
Ramdin, M., de Loos, T. W., & Vlugt, T. J. H. (2012) · Industrial & Engineering Chemistry Research · doi:10.1021/ie3003705 · Cited by 1,073
Gas Solubility in Ionic Liquids
Lei, Z., Dai, C., & Chen, B. (2014) · Chemical Reviews · doi:10.1021/cr300497a · Cited by 1,038
Metadata
- Authors
- Camper, D., Bara, J. E., Gin, D. L., & Noble, R. D.
- Venue
- Industrial & Engineering Chemistry Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-10-08
- Volume
- 47
- Issue
- 21
- Pages
- 8496-8498
- ISSN
- 0888-5885 (ISSN-L)
- 1520-5045
- OpenAlex
- W2025233477
- Cited by
- 442
- References
- 11
- FWCI
- 41.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.