CoChat

Comparison of Traditional and Structured Adsorbents for CO2 Separation by Vacuum-Swing Adsorption

Rezaei, Fateme, Mosca, Alessandra, Webley, Paul, Hedlund, Jonas, Xiao, Penny · 2010 · Industrial & Engineering Chemistry Research
Cited by 80

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The development of structured adsorbents with attractive characteristics is an important step in the improvement of adsorption-based gas-separation processes. The improved features of structured adsorbents include lower energy consumption, higher throughput, and superior recovery and purity of product because of the even flow distribution, very low mass-transfer resistance, and low pressure drop in combination with a reasonable adsorption capacity. This study examines the vacuum-swing adsorption (VSA) CO 2 separation performance of structured adsorbents in the form of thin NaX films grown on the walls of ceramic cordierite monoliths, and the results are compared with NaX pellets. Adsorption equilibrium and dynamic properties are explored experimentally. The CO 2 breakthrough front for the NaX film grown on the 400 cells/in. 2 (cpsi) monolith was close to ideal and indicated that axial dispersion was very small and that the mass-transfer resistance in the film was very low. The breakthrough front for the structured adsorbent with 400 cpsi was sharper than that for the structured adsorbent with 900 cpsi and only shifted to shorter breakthrough times because of the lower amount of zeolite and higher effective diffusivity of the former sample. In addition, the CO 2 breakthrough fronts for the 400 and 900 cpsi structured adsorbents were both sharper than the breakthrough front for NaX beads. This indicates that the flow distribution in the structured adsorbents is more even and that the mass-transfer resistance in the film is very low because of the small film thickness and high effective diffusivity for CO 2 in the NaX film. Experimental data were used to obtain overall mass-transfer linear-driving-force constants, which were subsequently used in a numerical simulation program to estimate the performance of the adsorbents for CO 2 /N 2 separation in a VSA process. It was found that the recovery of structured adsorbents was superior to that of a packed bed because of the much shorter mass-transfer zone. The purity, on the other hand, was not as high as that obtained with a packed bed because of excessive voidage in the structured adsorbents. Increased cell density or improved zeolite loading of the structured adsorbents would improve the CO 2 purity without sacrificing recovery for the structured adsorbents, and this represents a path forward to improved VSA performance for CO 2 capture.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ie9016545

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 80

Metadata

Authors
Rezaei, F., Mosca, A., Webley, P., Hedlund, J., & Xiao, P.
Venue
Industrial & Engineering Chemistry Research
Published
2010-04-12
Volume
49
Issue
10
Pages
4832-4841
ISSN
  • 0888-5885 (ISSN-L)
  • 1520-5045
OpenAlex
W2006872215
Cited by
80
References
2
FWCI
6.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Traditional and Structured Adsorbents for CO2 Separation by Vacuum-Swing Adsorption. https://app.cochat.ai/papers/10.1021/ie9016545
The paper
Rezaei, F., Mosca, A., Webley, P., Hedlund, J., & Xiao, P. (2010). Comparison of Traditional and Structured Adsorbents for CO2 Separation by Vacuum-Swing Adsorption. Industrial & Engineering Chemistry Research. https://doi.org/10.1021/ie9016545

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.