The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Membraneless Vanadium Redox Fuel Cell Using Laminar Flow
Abstract
This paper describes the design and characterization of a small, membraneless redox fuel cell. The smallest channel dimensions of the cell were 2 mm x 50 mum or x 200 mum; the cell was fabricated in poly(dimethylsiloxane) using soft lithography. This all-vanadium fuel cell took advantage of laminar flow to obviate the need for a membrane to separate the solutions of oxidizing and reducing components.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Self-citationChaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Self-citationA Group-IV Ferromagnetic Semiconductor: Mn x Ge 1− x
Park, Y. D., Hanbicki, A. T., Erwin, S. C., Hellberg, C. S., Sullivan, J. M., Mattson, J. E., Ambrose, T. F., Wilson, A., Spanos, G., & Jonker, B. T. (2002) · Science · doi:10.1126/science.1066348 · Cited by 1,631
A study of the V(II)/V(III) redox couple for redox flow cell applications
Sum, E., & Skyllas‐Kazacos, M. (1985) · Journal of Power Sources · doi:10.1016/0378-7753(85)80071-9 · Cited by 667
Ismagilov, R. F., Stroock, A. D., Kenis, P. J. A., Whitesides, G., & Stone, H. A. (2000) · Applied Physics Letters · doi:10.1063/1.126351 · Cited by 540
Self-citationChen, T., Barton, S. C., Binyamin, G., Gao, Z., Zhang, Y., Kim, H.-H., & Heller, A. (2001) · Journal of the American Chemical Society · doi:10.1021/ja0163164 · Cited by 427
Coplanar interdigitated band electrodes for synthesis Part I: Ohmic loss evaluation
Belmont, C., & Girault, H. H. (1994) · Journal of Applied Electrochemistry · doi:10.1007/bf00249845 · Cited by 33
Cited by
Progress in Flow Battery Research and Development
Skyllas-Kazacos, M., Chakrabarti, M. H., Hajimolana, S. A., Mjalli, F. S., & Saleem, M. (2011) · Journal of The Electrochemical Society · doi:10.1149/1.3599565 · Cited by 1,453
Industrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.017 · Cited by 313
A high performance dual electrolyte microfluidic reactor for the utilization of CO2
Lu, X., Leung, D. Y. C., Wang, H., & Xuan, J. (2017) · Applied Energy · doi:10.1016/j.apenergy.2016.05.091 · Cited by 84
Li, F., Macdonald, N. P., Guijt, R. M., & Breadmore, M. C. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b03228 · Cited by 74
Membraneless laminar flow cell for electrocatalytic CO 2 reduction with liquid product separation
Monroe, M. M., Lobaccaro, P., Lum, Y., & Ager, J. W. (2017) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/aa6359 · Cited by 30
Metadata
- Authors
- Ferrigno, R., Stroock, A. D., Clark, T. D., Mayer, M., & Whitesides, G. M.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-10-15
- Volume
- 124
- Issue
- 44
- Pages
- 12930-12931
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1984684733
- Cited by
- 481
- References
- 7
- FWCI
- 10.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.