Evidence of Surfactant-Induced Formation of Transient Pores in Lipid Bilayers by Using Magnetic-Fluid-Loaded Liposomes
The DOI matches its Crossref record.
Abstract
It is often assumed that surfactant-induced permeability of lipid membranes obeys a pore-formation mechanism, but, to date, this has not been totally proven. A novel approach is developed using a magnetic fluid composed of calibrated nanocrystals of maghemite (gamma-Fe2O3) as a permeability marker. It is shown that low amounts of surfactant molecules catalyze the transient opening of unilamellar phospholipid vesicles which permit the passage of 8 nm maghemite nanospheres before closing up.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852
Hybrid Nanoparticles for Detection and Treatment of Cancer
Sailor, M. J., & Park, J. (2012) · Advanced Materials · doi:10.1002/adma.201200653 · Cited by 487
(2007) · doi:10.1007/978-3-540-37885-3 · Cited by 476
Martina, M.-S., Fortin, J.-P., Ménager, C., Clément, O., Barratt, G., Grabielle-Madelmont, C., Gazeau, F., Cabuil, V., & Lesieur, S. (2005) · Journal of the American Chemical Society · doi:10.1021/ja0516460 · Cited by 441
Self-citationProgress in the preparation of magnetic nanoparticles for applications in biomedicine
Roca, A. G., Costo, R., Rebolledo, A. F., Veintemillas-Verdaguer, S., Tartaj, P., González-Carreño, T., Morales, M. P., & Serna, C. J. (2009) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/42/22/224002 · Cited by 412
Interactions of surfactants with lipid membranes
Heerklotz, H. (2008) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583508004721 · Cited by 339
Zhang, L., Qiao, S. Z., Jin, Y. G., Chen, Z. G., Gu, H. C., & Lu, G. Q. (2008) · Advanced Materials · doi:10.1002/adma.200700900 · Cited by 285
Magnetic Nanoparticles as MRI Contrast Agents
Avasthi, A., Caro, C., Pozo-Torres, E., Leal, M. P., & García-Martín, M. L. (2020) · Topics in Current Chemistry · doi:10.1007/s41061-020-00302-w · Cited by 253
Fortin-Ripoche, J.-P., Martina, M. S., Gazeau, F., Ménager, C., Wilhelm, C., Bacri, J.-C., Lesieur, S., & Clément, O. (2006) · Radiology · doi:10.1148/radiol.2392042110 · Cited by 148
Self-citationMagnetoliposomes for controlled drug release in the presence of low-frequency magnetic field
Nappini, S., Bombelli, F. B., Bonini, M., Nordèn, B., & Baglioni, P. (2010) · Soft Matter · doi:10.1039/b915651h · Cited by 113
Yang, L., Patel, K. D., Rathnam, C., Thangam, R., Hou, Y., Kang, H., & Lee, K. (2022) · Small · doi:10.1002/smll.202104783 · Cited by 81
Jabalera, Y., Fernández-Vivas, A., Iglesias, G. R., Delgado, Á. V., & Jimenez-Lopez, C. (2019) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2019.110435 · Cited by 32
Metadata
- Authors
- Lesieur, S., Grabielle-Madelmont, C., Ménager, C., Cabuil, V., Dadhi, D., Pierrot, P., & Edwards, K.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-04-10
- Volume
- 125
- Issue
- 18
- Pages
- 5266-5267
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2057396158
- Cited by
- 81
- References
- 0
- FWCI
- 1.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.