Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 549

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Stimuli-Responsive Supramolecular Assemblies of Linear-Dendritic Copolymers

Gillies, Elizabeth R., Jonsson, Thomas B., Fréchet, Jean M. J.·2004·Journal of the American Chemical Society

Abstract

With the goal of developing a pH-responsive micelle system, linear-dendritic block copolymers comprising poly(ethylene oxide) and either a polylysine or polyester dendron were prepared and hydrophobic groups were attached to the dendrimer periphery by highly acid-sensitive cyclic acetals. These copolymers were designed to form stable micelles in aqueous solution at neutral pH but to disintegrate into unimers at mildly acidic pH following loss of the hydrophobic groups upon acetal hydrolysis. Micelle formation was demonstrated by encapsulation of the fluorescent probe Nile Red, and the micelle sizes were determined by dynamic light scattering. The structure of the dendrimer block, its generation, and the synthetic method for linking the acetal groups to its periphery all had an influence on the critical micelle concentration and the micelle size. The rate of hydrolysis of the acetals at the micelle core was measured for each system at pH 7.4 and pH 5, and it was found that all systems were stable at neutral pH but underwent significant hydrolysis at pH 5 over several hours. The rate of hydrolysis at pH 5 was dependent on the structure of the copolymer, most notably the hydrophobicity of the core-forming block. To demonstrate the potential of these systems for controlled release, the release of Nile Red as a "model payload" was examined. At pH 7.4, the fluorescence of micelle-encapsulated Nile Red was relatively constant, indicating it was retained in the micelle, while at pH 5, the fluorescence decreased, consistent with its release into the aqueous environment. The rate of release was strongly correlated with the rate of acetal hydrolysis and was therefore controlled by the chemical structure of the copolymer. The mechanism of Nile Red release was investigated by monitoring the change in size of the micelles over time at acidic pH. Dynamic light scattering measurement showed a size decrease over time, eventually reaching the size of a unimer, thus providing evidence for the proposed micelle disintegration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ja0463738

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 549

Metadata

Authors
Gillies, E. R., Jonsson, T. B., & Fréchet, J. M. J.
Venue
Journal of the American Chemical Society
Published
2004-09-01
Volume
126
Issue
38
Pages
11936-11943
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W1996292197
Cited by
549
References
19
FWCI
23.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Stimuli-Responsive Supramolecular Assemblies of Linear-Dendritic Copolymers. https://app.cochat.ai/papers/10.1021/ja0463738
The paper
Gillies, E. R., Jonsson, T. B., & Fréchet, J. M. J. (2004). Stimuli-Responsive Supramolecular Assemblies of Linear-Dendritic Copolymers. Journal of the American Chemical Society. https://doi.org/10.1021/ja0463738

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.