The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
4,5-Dimethylthio-4‘-[2-(9-anthryloxy)ethylthio]tetrathiafulvalene, a Highly Selective and Sensitive Chemiluminescence Probe for Singlet Oxygen
Abstract
4,5-Dimethylthio-4'-[2-(9-anthryloxy)ethylthio]tetrathiafulvalene has been designed and synthesized as a highly selective and sensitive chemiluminescence (CL) probe for singlet oxygen ((1)O(2)). The design strategy for the probe is directed by the idea of photoinduced electron-transfer process and carried out through the incorporation of electron-rich tetrathiafulvalene unit into a reactive luminophore of anthracene specific for (1)O(2). Upon reaction with reactive oxygen species (ROS), such as hydrogen peroxide, hypochlorite, superoxide, hydroxyl radical, or (1)O(2), the probe exhibits both strong CL response to and high selectivity for (1)O(2) only, rather than the other ROS. This remarkable CL property permits (1)O(2) to be distinguished easily from the other ROS and makes the probe possible to be used widely for (1)O(2) detection in many chemical and biological systems and even in light water (H(2)O) environments. This applicability has been demonstrated by monitoring the (1)O(2) generation in a metal-catalyzed decomposition system of tert-butyl hydroperoxide. Moreover, the CL reaction mechanism of the present system is also discussed, clearly confirming that the introduction of electron-rich tetrathiafulvalene into the 9-position of anthracene can greatly activate its reactivity toward (1)O(2).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Pecking Order of Free Radicals and Antioxidants: Lipid Peroxidation, α-Tocopherol, and Ascorbate
Buettner, G. R. (1993) · Archives of Biochemistry and Biophysics · doi:10.1006/abbi.1993.1074 · Cited by 2,417
Physical Mechanisms of Generation and Deactivation of Singlet Oxygen
Schweitzer, C., & Schmidt, R. (2003) · Chemical Reviews · doi:10.1021/cr010371d · Cited by 2,123
Cited by
Fluorescent and luminescent probes for detection of reactive oxygen and nitrogen species
Chen, X., Tian, X., Shin, I., & Yoon, J. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15037e · Cited by 980
Wan, Q., Chen, S., Shi, W., Li, L., & Ma, H. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201405742 · Cited by 420
Self-citationSinglet-Oxygen Chemiluminescence in Peroxide Reactions
Adam, W., Kazakov, D. V., & Kazakov, V. P. (2005) · Chemical Reviews · doi:10.1021/cr0300035 · Cited by 313
Yang, Y.-K., Cho, H. J., Lee, J., Shin, I., & Tae, J. (2009) · Organic Letters · doi:10.1021/ol802822t · Cited by 276
A Highly Selective and Sensitive Fluorescence Probe for the Hypochlorite Anion
Chen, X., Wang, X., Wang, S., Shi, W., Wang, K., & Ma, H. (2008) · Chemistry – A European Journal · doi:10.1002/chem.200701677 · Cited by 264
Self-citation
Metadata
- Authors
- Li, X., Zhang, G., Ma, H., Zhang, D., Li, J., & Zhu, D.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-08-26
- Volume
- 126
- Issue
- 37
- Pages
- 11543-11548
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1978681149
- Cited by
- 238
- References
- 2
- FWCI
- 3.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.