The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A Rhodamine−Hydroxamic Acid-Based Fluorescent Probe for Hypochlorous Acid and Its Applications to Biological Imagings
Abstract
A new rhodamine-hydroxamic acid-based fluorescent chemosensor for the rapid detection of HOCl in aqueous media was developed. The system, which utilizes an irreversible HOCl-promoted oxidation reaction, responds instantaneously at room temperature with linear proportionality to the amount of HOCl. This system is highly selective for HOCl over other reactive oxygen species (ROS) and highly sensitive in aqueous solutions. Biological imaging studies using living cells and organisms (A549 cells and zebrafish) to detect HOCl are successfully demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pattison, D. I., & Davies, M. J. (2001) · Chemical Research in Toxicology · doi:10.1021/tx0155451 · Cited by 790
Kawai, Y., Kiyokawa, H., Kimura, Y., Kato, Y., Tsuchiya, K., & Terao, J. (2006) · Biochemistry · doi:10.1021/bi0610909 · Cited by 78
Cited by
Fluorescent and luminescent probes for detection of reactive oxygen and nitrogen species
Chen, X., Tian, X., Shin, I., & Yoon, J. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15037e · Cited by 980
Self-citationZhao, Y., Zhang, X.-B., Han, Z.-X., Qiao, L., Li, C.-Y., Jian, L.-X., Shen, G.-L., & Yu, R.-Q. (2009) · Analytical Chemistry · doi:10.1021/ac901127n · Cited by 455
Hybrid Rhodamine Fluorophores in the Visible/NIR Region for Biological Imaging
Wang, L., Du, W., Hu, Z., Uvdal, K., Li, L., & Huang, W. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201901061 · Cited by 348
Chen, X., Lee, K.-A., Ha, E.-M., Lee, K. M., Seo, Y. Y., Choi, H. K., Kim, H. N., Kim, M. J., Cho, C.-S., Lee, S. Y., et al. (2011) · Chemical Communications · doi:10.1039/c1cc10589b · Cited by 246
Dong, X., Zhang, G., Shi, J., Wang, Y., Wang, M., Peng, Q., & Zhang, D. (2017) · Chem. Commun. · doi:10.1039/c7cc07092f · Cited by 54
Metadata
- Authors
- Yang, Y.-K., Cho, H. J., Lee, J., Shin, I., & Tae, J.
- Venue
- Organic Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-01-23
- Volume
- 11
- Issue
- 4
- Pages
- 859-861
- ISSN
- 1523-7052 (ISSN-L)
- 1523-7060
- OpenAlex
- W1995626391
- Cited by
- 276
- References
- 2
- FWCI
- 9.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Rhodamine−Hydroxamic Acid-Based Fluorescent Probe for Hypochlorous Acid and Its Applications to Biological Imagings. https://app.cochat.ai/papers/10.1021/ol802822t
- The paper
- Yang, Y.-K., Cho, H. J., Lee, J., Shin, I., & Tae, J. (2009). A Rhodamine−Hydroxamic Acid-Based Fluorescent Probe for Hypochlorous Acid and Its Applications to Biological Imagings. Organic Letters. https://doi.org/10.1021/ol802822t
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.