The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
High-Temperature Microfluidic Synthesis of CdSe Nanocrystals in Nanoliter Droplets
Abstract
The high-temperature synthesis of CdSe nanocrystals in nanoliter-volume droplets flowing in a perfluorinated carrier fluid through a microfabricated reactor is presented. A flow-focusing nanojet structure with a step increase in channel height reproducibly generated octadecene droplets in Fomblin Y 06/6 perfluorinated polyether at capillary numbers up to 0.81 and with a droplet:carrier fluid viscosity ratio of 0.035. Cadmium and selenium precursors flowing in octadecene droplets through a high-temperature (240-300 degrees C) glass microreactor produced high-quality CdSe nanocrystals, as verified by optical spectroscopy and transmission electron microscopy. Isolating the reaction solution in droplets prevented particle deposition and hydrodynamic dispersion, allowing the reproducible synthesis of nanocrystals at three different temperatures and four different residence times in the span of 4 h. Our synthesis of a wide range of nanocrystals at high temperatures, high capillary numbers, and low viscosity ratio illustrates the general utility of droplet-based microfluidic reactors to encapsulate nanoliter volumes of organic or aqueous solutions and to precisely control chemical or biochemical reactions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic Pattern Formation in a Vesicle-Generating Microfluidic Device
Thorsen, T., Roberts, R. W., Arnold, F. H., & Quake, S. R. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.4163 · Cited by 2,051
Microreaction engineering — is small better?
Jensen, K. F. (2001) · Chemical Engineering Science · doi:10.1016/s0009-2509(00)00230-x · Cited by 1,124
Preparation of nanoparticles via spray route
Okuyama, K., & Wuled Lenggoro, I. (2003) · Chemical Engineering Science · doi:10.1016/s0009-2509(02)00578-x · Cited by 648
Shestopalov, I., Tice, J. D., & Ismagilov, R. F. (2004) · Lab on a Chip · doi:10.1039/b403378g · Cited by 571
Transport and reaction in microscale segmented gas–liquid flow
Günther, A., Khan, S. A., Thalmann, M., Trachsel, F., & Jensen, K. F. (2004) · Lab Chip · doi:10.1039/b403982c · Cited by 534
The intensification of rapid reactions in multiphase systems using slug flow in capillaries
Burns, J. R., & Ramshaw, C. (2001) · Lab on a Chip · doi:10.1039/b102818a · Cited by 503
An experimental study of transient effects in the breakup of viscous drops
Stone, H. A., Bentley, B. J., & Leal, L. G. (1986) · Journal of Fluid Mechanics · doi:10.1017/s0022112086001118 · Cited by 455
Interfacial Tension Driven Monodispersed Droplet Formation from Microfabricated Channel Array
Sugiura, S., Nakajima, M., Iwamoto, S., & Seki, M. (2001) · Langmuir · doi:10.1021/la010342y · Cited by 439
Srinivasan, U., Houston, M. R., Howe, R. T., & Maboudian, R. (1998) · Journal of Microelectromechanical Systems · doi:10.1109/84.679393 · Cited by 422
Steckel, J. S., Coe‐Sullivan, S., Bulović, V., & Bawendi, M. G. (2003) · Advanced Materials · doi:10.1002/adma.200305449 · Cited by 416
Microemulsion dynamics and reactions in microemulsions
López-Quintela, M. A., Tojo, C., Blanco, M. C., Garcı́a Rio, L., & Leis, J. R. (2004) · Current Opinion in Colloid & Interface Science · doi:10.1016/j.cocis.2004.05.029 · Cited by 397
Nucleation and Growth Kinetics of CdSe Nanocrystals in Octadecene
Bullen, C. R., & Mulvaney, P. A. (2004) · Nano Letters · doi:10.1021/nl0496724 · Cited by 393
Levenspiel, O. (1979) · Cited by 344
Vesicles and Polymerized Vesicles from Thiophene‐Containing Rod–Coil Block Copolymers
Vriezema, D. M., Hoogboom, J., Velonia, K., Takazawa, K., Christianen, P. C. M., Maan, J. C., Rowan, A. E., & Nolte, R. J. M. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200390204 · Cited by 334
Zheng, B., Tice, J. D., & Ismagilov, R. F. (2004) · Analytical Chemistry · doi:10.1021/ac0495743 · Cited by 321
Fully integrated PCR-capillary electrophoresis microsystem for DNA analysis
Lagally, E. T., Emrich, C. A., & Mathies, R. A. (2001) · Lab on a Chip · doi:10.1039/b109031n · Cited by 284
Self-citationThermocapillary pumping of discrete drops in microfabricated analysis devices
Sammarco, T. S., & Burns, M. A. (1999) · AIChE Journal · doi:10.1002/aic.690450215 · Cited by 282
Benchmarking of Microreactor Applications
Pennemann, H., Watts, P., Haswell, S. J., Hessel, V., & Löwe, H. (2004) · Organic Process Research & Development · doi:10.1021/op0341770 · Cited by 209
On-line analysis of CdSe nanoparticle formation in a continuous flow chip-based microreactor
Krishnadasan, S. H., Tovilla, J. A., Vilar, R., deMello, A. J., & deMello, J. C. (2004) · Journal of Materials Chemistry · doi:10.1039/b401559b · Cited by 144
A numerical model for segmented flow in a microreactor
Harries, N., Burns, J. R., Barrow, D. A., & Ramshaw, C. (2003) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(03)00120-0 · Cited by 127
Cited by
Teh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Emerging Droplet Microfluidics
Shang, L., Cheng, Y., & Zhao, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00848 · Cited by 1,584
Control and detection of chemical reactions in microfluidic systems
deMello, A. J. (2006) · Nature · doi:10.1038/nature05062 · Cited by 1,495
Passive and active droplet generation with microfluidics: a review
Zhu, P., & Wang, L. (2017) · Lab on a Chip · doi:10.1039/c6lc01018k · Cited by 1,238
Metadata
- Authors
- Chan, E. M., Alivisatos, A. P., & Mathies, R. A.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-09-21
- Volume
- 127
- Issue
- 40
- Pages
- 13854-13861
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2120179009
- Cited by
- 376
- References
- 20
- FWCI
- 14.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.