The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Development of an Iminocoumarin-Based Zinc Sensor Suitable for Ratiometric Fluorescence Imaging of Neuronal Zinc
Abstract
Ratiometric imaging is a technique to reduce artifacts by minimizing the influence of extraneous factors on the fluorescence of a sensor and is particularly useful for cellular imaging studies. Here we characterized the iminocoumarin fluorophore as a new scaffold for sensors for ratiometric imaging. The iminocoumarin 4 showed a high quantum yield in aqueous media on excitation in the visible wavelength region, while its coumarin analogue showed little fluorescence. We therefore developed a novel fluorescence probe, ZnIC, for ratiometric imaging of Zn2+, using iminocoumarin as a fluorophore and (ethylamino)dipicolylamine as a Zn2+ chelator. ZnIC exhibited almost the same fluorescence properties as 4, and the emission spectrum of this probe was red-shifted on addition of Zn2+ under physiological conditions. ZnIC is selective for Zn2+ over other biologically important metal ions, such as Ca2+ and Mg2+, and has high affinity for Zn2+. To confirm the suitability of ZnIC for biological applications, we employed it for the ratiometric detection of changes in intracellular Zn2+ in cultured cells and in rat hippocampal slices. The results indicate that iminocoumarin is a useful fluorophore for fluorescence microscopic imaging and that ZnIC should be useful for studies on the biological functions of Zn2+.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new generation of Ca2+ indicators with greatly improved fluorescence properties.
Grynkiewicz, G., Poenie, M., & Tsien, R. Y. (1985) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)83641-4 · Cited by 21,607
The biochemical basis of zinc physiology
Vallee, B. L., & Falchuk, K. H. (1993) · Physiological Reviews · doi:10.1152/physrev.1993.73.1.79 · Cited by 2,990
Design principles of fluorescent molecular sensors for cation recognition
Valeur, B. (2000) · Coordination Chemistry Reviews · doi:10.1016/s0010-8545(00)00246-0 · Cited by 2,377
Release of endogenous Zn2+ from brain tissue during activity
Assaf, S. Y., & Chung, S.-H. (1984) · Nature · doi:10.1038/308734a0 · Cited by 1,118
Handbook of fluorescent probes and research products
Haugland, R. P. (2002) · Cited by 1,032
Jiang, P., & Guo, Z. (2004) · Coordination Chemistry Reviews · doi:10.1016/j.cct.2003.10.013 · Cited by 989
Effects of Angiogenesis Inhibitors on Multistage Carcinogenesis in Mice
Bergers, G., Javaherian, K., Lo, K.-M., Folkman, J., & Hanahan, D. (1999) · Science · doi:10.1126/science.284.5415.808 · Cited by 988
Buffers for pH and Metal Ion Control.
Perrin, D. D., & Dempsey, B. (1975) · Journal of AOAC INTERNATIONAL · doi:10.1093/jaoac/58.4.864 · Cited by 872
Stimulation-induced uptake and release of zinc in hippocampal slices
Howell, G. A., Welch, M. G., & Frederickson, C. J. (1984) · Nature · doi:10.1038/308736a0 · Cited by 803
Burdette, S. C., Walkup, G. K., Spingler, B., Tsien, R. Y., & Lippard, S. J. (2001) · Journal of the American Chemical Society · doi:10.1021/ja010059l · Cited by 744
Cited by
Design Strategies for Water-Soluble Small Molecular Chromogenic and Fluorogenic Probes
Li, X., Gao, X., Shi, W., & Ma, H. (2014) · Chemical Reviews · doi:10.1021/cr300508p · Cited by 1,729
Small molecule-based ratiometric fluorescence probes for cations, anions, and biomolecules
Lee, M. H., Kim, J. S., & Sessler, J. L. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00280f · Cited by 1,642
Recent Development of Chemosensors Based on Cyanine Platforms
Sun, W., Guo, S., Hu, C., Fan, J., & Peng, X. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00001 · Cited by 1,109
Jung, H. S., Kwon, P. S., Lee, J. W., Kim, J. I., Hong, C. S., Kim, J. W., Yan, S., Lee, J. Y., Lee, J. H., Joo, T., et al. (2009) · Journal of the American Chemical Society · doi:10.1021/ja808611d · Cited by 1,058
Fluorescent chemosensors for Zn2+
Xu, Z., Yoon, J., & Spring, D. R. (2010) · Chemical Society Reviews · doi:10.1039/b916287a · Cited by 982
Xu, Z., Baek, K.-H., Kim, H. N., Cui, J., Qian, X., Spring, D. R., Shin, I., & Yoon, J. (2010) · Journal of the American Chemical Society · doi:10.1021/ja907334j · Cited by 692
In Situ Imaging of Metals in Cells and Tissues
McRae, R., Bagchi, P., Sumalekshmy, S., & Fahrni, C. J. (2009) · Chemical Reviews · doi:10.1021/cr900223a · Cited by 570
Zhao, Y., Zhang, X.-B., Han, Z.-X., Qiao, L., Li, C.-Y., Jian, L.-X., Shen, G.-L., & Yu, R.-Q. (2009) · Analytical Chemistry · doi:10.1021/ac901127n · Cited by 455
Fluorescent probes for bioimaging applications
Terai, T., & Nagano, T. (2008) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2008.08.007 · Cited by 440
Self-citationQian, F., Zhang, C., Zhang, Y., He, W., Gao, X., Hu, P., & Guo, Z. (2009) · Journal of the American Chemical Society · doi:10.1021/ja806489y · Cited by 424
Cheng, T., Xu, Y., Zhang, S., Zhu, W., Qian, X., & Duan, L. (2008) · Journal of the American Chemical Society · doi:10.1021/ja806928n · Cited by 339
Photoluminescence imaging of Zn2+in living systems
Chen, Y., Bai, Y., Han, Z., He, W., & Guo, Z. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00005j · Cited by 267
A Ratiometric Fluorescent Probe for Hypochlorite Based on a Deoximation Reaction
Lin, W., Long, L., Chen, B., & Tan, W. (2009) · Chemistry – A European Journal · doi:10.1002/chem.200802054 · Cited by 264
Metadata
- Authors
- Komatsu, K., Urano, Y., Kojima, H., & Nagano, T.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-10-10
- Volume
- 129
- Issue
- 44
- Pages
- 13447-13454
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2039367065
- Cited by
- 542
- References
- 32
- FWCI
- 12.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.