Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 431

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Fluorescence Ratiometry and Fluorescence Lifetime Imaging: Using a Single Molecular Sensor for Dual Mode Imaging of Cellular Viscosity

Peng, Xiaojun, Yang, Zhigang, Wang, Jingyun, Fan, Jiangli, He, Yanxia, Song, Fengling, Wang, Bingshuai, Sun, Shiguo, Qu, Junle, Qi, Jing, Yan, Meng·2011·Journal of the American Chemical Society

Abstract

Intracellular viscosity strongly influences transportation of mass and signal, interactions between the biomacromolecules, and diffusion of reactive metabolites in live cells. Fluorescent molecular rotors are recently developed reagents used to determine the viscosity in solutions or biological fluid. Due to the complexity of live cells, it is important to carry out the viscosity determinations in multimode for high reliability and accuracy. The first molecular rotor (RY3) capable of dual mode fluorescence imaging (ratiometry imaging and fluorescence lifetime imaging) of intracellular viscosity is reported. RY3 is a pentamethine cyanine dye substituted at the central (meso-) position with an aldehyde group (CHO). In nonviscous media, rotation of the CHO group gives rise to internal conversion by a nonradiative process. The restraining of rotation in viscous or low-temperature media results in strong fluorescence (6-fold increase) and lengthens the fluorescence lifetime (from 200 to 1450 ps). The specially designed molecular sensor has two absorption maxima (λ(abs) 400 and 613 nm in ethanol) and two emission maxima (in blue, λ(em) 456 nm and red, 650 nm in ethanol). However it is only the red emission which is markedly sensitive to viscosity or temperature changes, providing a ratiometric response (12-fold) as well as a large pseudo-Stokes shift (250 nm). A mechanism is proposed, based on quantum chemical calculations and (1)H NMR spectra at low-temperature. Inside cells the viscosity changes, showing some regional differences, can be clearly observed by both ratiometry imaging and fluorescence lifetime imaging (FLIM). Although living cells are complex the correlation observed between the two imaging procedures offers the possibility of previously unavailable reliability and accuracy when determining intracellular viscosity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ja1104014

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 30 references

Cited by

Metadata

Authors
Peng, X., Yang, Z., Wang, J., Fan, J., He, Y., Song, F., Wang, B., Sun, S., Qu, J., Qi, J., & Yan, M.
Venue
Journal of the American Chemical Society
Published
2011-04-08
Volume
133
Issue
17
Pages
6626-6635
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W1978552755
Cited by
431
References
30
FWCI
10.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.