The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Fluorescence Ratiometry and Fluorescence Lifetime Imaging: Using a Single Molecular Sensor for Dual Mode Imaging of Cellular Viscosity
Abstract
Intracellular viscosity strongly influences transportation of mass and signal, interactions between the biomacromolecules, and diffusion of reactive metabolites in live cells. Fluorescent molecular rotors are recently developed reagents used to determine the viscosity in solutions or biological fluid. Due to the complexity of live cells, it is important to carry out the viscosity determinations in multimode for high reliability and accuracy. The first molecular rotor (RY3) capable of dual mode fluorescence imaging (ratiometry imaging and fluorescence lifetime imaging) of intracellular viscosity is reported. RY3 is a pentamethine cyanine dye substituted at the central (meso-) position with an aldehyde group (CHO). In nonviscous media, rotation of the CHO group gives rise to internal conversion by a nonradiative process. The restraining of rotation in viscous or low-temperature media results in strong fluorescence (6-fold increase) and lengthens the fluorescence lifetime (from 200 to 1450 ps). The specially designed molecular sensor has two absorption maxima (λ(abs) 400 and 613 nm in ethanol) and two emission maxima (in blue, λ(em) 456 nm and red, 650 nm in ethanol). However it is only the red emission which is markedly sensitive to viscosity or temperature changes, providing a ratiometric response (12-fold) as well as a large pseudo-Stokes shift (250 nm). A mechanism is proposed, based on quantum chemical calculations and (1)H NMR spectra at low-temperature. Inside cells the viscosity changes, showing some regional differences, can be clearly observed by both ratiometry imaging and fluorescence lifetime imaging (FLIM). Although living cells are complex the correlation observed between the two imaging procedures offers the possibility of previously unavailable reliability and accuracy when determining intracellular viscosity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stratmann, R. E., Scuseria, G. E., & Frisch, M. J. (1998) · The Journal of Chemical Physics · doi:10.1063/1.477483 · Cited by 5,099
Dreizler, R. M., & Gross, E. K. U. (1990) · Springer eBooks · doi:10.1007/978-3-642-86105-5 · Cited by 2,570
Time-Correlated Single Photon Counting
(1984) · Elsevier eBooks · doi:10.1016/b978-0-12-524140-3.x5001-1 · Cited by 2,550
Shedding light onto live molecular targets
Weissleder, R., & Ntziachristos, V. (2003) · Nature Medicine · doi:10.1038/nm0103-123 · Cited by 1,909
Kurth, S., Marques, M. A. L., & Gross, E. K. U. (2005) · Encyclopedia of Condensed Matter Physics · doi:10.1016/b0-12-369401-9/00445-9 · Cited by 1,370
Luby-Phelps, K. (1999) · International Review of Cytology · doi:10.1016/s0074-7696(08)60527-6 · Cited by 1,149
CFTR as a cAMP-Dependent Regulator of Sodium Channels
Stutts, M. J., Canessa, C. M., Olsen, J. C., Hamrick, M., Cohn, J. A., Rossier, B. C., & Boucher, R. C. (1995) · Science · doi:10.1126/science.7543698 · Cited by 1,088
Local density-functional theory of frequency-dependent linear response
Gross, E. K. U., & Kohn, W. (1985) · Physical Review Letters · doi:10.1103/physrevlett.55.2850 · Cited by 1,085
Advanced Time-Correlated Single Photon Counting Techniques
Becker, W. (2005) · Springer Series in Chemical Physics · doi:10.1007/3-540-28882-1 · Cited by 1,019
Fabian, J., Nakazumi, H., & Matsuoka, M. (1992) · Chemical Reviews · doi:10.1021/cr00014a003 · Cited by 969
Cited by
Xi, D., Xiao, M., Cao, J., Zhao, L., Xu, N., Long, S., Fan, J., Shao, K., Sun, W., Yan, X., et al. (2020) · Advanced Materials · doi:10.1002/adma.201907855 · Cited by 658
Self-citationAnti-quenching NIR-II molecular fluorophores for in vivo high-contrast imaging and pH sensing
Wang, S., Fan, Y., Li, D., Sun, C., Lei, Z., Lu, L., Wang, T., & Zhang, F. (2019) · Nature Communications · doi:10.1038/s41467-019-09043-x · Cited by 510
Xiong, X., Song, F., Wang, J., Zhang, Y., Xue, Y., Sun, L., Jiang, N., Gao, P., Tian, L., & Peng, X. (2014) · Journal of the American Chemical Society · doi:10.1021/ja502292p · Cited by 326
Self-citationFluorescent Polymer Nanoparticles for Cell Barcoding In Vitro and In Vivo
Andreiuk, B., Reisch, A., Lindecker, M., Follain, G., Peyriéras, N., Goetz, J. G., & Klymchenko, A. S. (2017) · Small · doi:10.1002/smll.201701582 · Cited by 129
Activatable Molecular Probes With Clinical Promise for NIR‐II Fluorescent Imaging
Chen, Z., Zhou, Y., Li, L., Ma, W., Li, Y., & Yang, Z. (2025) · Small · doi:10.1002/smll.202411787 · Cited by 26
Self-citation
Metadata
- Authors
- Peng, X., Yang, Z., Wang, J., Fan, J., He, Y., Song, F., Wang, B., Sun, S., Qu, J., Qi, J., & Yan, M.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-04-08
- Volume
- 133
- Issue
- 17
- Pages
- 6626-6635
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1978552755
- Cited by
- 431
- References
- 30
- FWCI
- 10.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.