The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
A Targetable Fluorescent Sensor Reveals That Copper-Deficient SCO1 and SCO2 Patient Cells Prioritize Mitochondrial Copper Homeostasis
Open accessAbstract
We present the design, synthesis, spectroscopy, and biological applications of Mitochondrial Coppersensor-1 (Mito-CS1), a new type of targetable fluorescent sensor for imaging exchangeable mitochondrial copper pools in living cells. Mito-CS1 is a bifunctional reporter that combines a Cu(+)-responsive fluorescent platform with a mitochondrial-targeting triphenylphosphonium moiety for localizing the probe to this organelle. Molecular imaging with Mito-CS1 establishes that this new chemical tool can detect changes in labile mitochondrial Cu(+) in a model HEK 293T cell line as well as in human fibroblasts. Moreover, we utilized Mito-CS1 in a combined imaging and biochemical study in fibroblasts derived from patients with mutations in the two synthesis of cytochrome c oxidase 1 and 2 proteins (SCO1 and SCO2), each of which is required for assembly and metalation of functionally active cytochrome c oxidase (COX). Interestingly, we observe that although defects in these mitochondrial metallochaperones lead to a global copper deficiency at the whole cell level, total copper and exchangeable mitochondrial Cu(+) pools in SCO1 and SCO2 patient fibroblasts are largely unaltered relative to wild-type controls. Our findings reveal that the cell maintains copper homeostasis in mitochondria even in situations of copper deficiency and mitochondrial metallochaperone malfunction, illustrating the importance of regulating copper stores in this energy-producing organelle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
BODIPY Dyes and Their Derivatives: Syntheses and Spectroscopic Properties
Loudet, A., & Burgess, K. (2007) · Chemical Reviews · doi:10.1021/cr078381n · Cited by 5,238
p53 Regulates Mitochondrial Respiration
Matoba, S., Kang, J.-G., Patino, W. D., Wragg, A., Boehm, M., Gavrilova, O., Hurley, P. J., Bunz, F., & Hwang, P. M. (2006) · Science · doi:10.1126/science.1126863 · Cited by 1,650
Targeting Antioxidants to Mitochondria by Conjugation to Lipophilic Cations
Murphy, M. P., & Smith, R. A. J. (2007) · Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev.pharmtox.47.120505.105110 · Cited by 1,173
Selective fluorescent imaging of superoxide in vivo using ethidium-based probes
Robinson, K. M., Janes, M. S., Pehar, M., Monette, J. S., Ross, M. F., Hagen, T. M., Murphy, M. P., & Beckman, J. S. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0601945103 · Cited by 777
A Role for the ATP7A Copper-transporting ATPase in Macrophage Bactericidal Activity
White, C., Lee, J., Kambe, T., Fritsche, K., & Petris, M. J. (2009) · Journal of Biological Chemistry · doi:10.1074/jbc.m109.070201 · Cited by 524
Mitochondrial copper metabolism and delivery to cytochrome c oxidase
Horn, D., & Barrientos, A. (2008) · IUBMB Life · doi:10.1002/iub.50 · Cited by 283
Metal Acquisition and Availability in the Mitochondria
Atkinson, A., & Winge, D. R. (2009) · Chemical Reviews · doi:10.1021/cr900006y · Cited by 146
Self-citationPorteous, C. M., Logan, A., Evans, C., Ledgerwood, E. C., Menon, D. K., Aigbirhio, F., Smith, R. A. J., & Murphy, M. P. (2010) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2010.06.001 · Cited by 121
Cited by
Fluorescent Probes for Sensing and Imaging within Specific Cellular Organelles
Zhu, H., Fan, J., Du, J., & Peng, X. (2016) · Accounts of Chemical Research · doi:10.1021/acs.accounts.6b00292 · Cited by 984
Cuproptosis: mechanisms and links with cancers
Xie, J., Yang, Y., Gao, Y., & He, J. (2023) · Molecular Cancer · doi:10.1186/s12943-023-01732-y · Cited by 801
Metal coordination in photoluminescent sensing
Liu, Z., He, W., & Guo, Z. (2013) · Chemical Society Reviews · doi:10.1039/c2cs35363f · Cited by 800
Synthetic fluorescent probes for studying copper in biological systems
Cotruvo, Jr., Aron, A. T., Ramos-Torres, K. M., & Chang, C. J. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00346b · Cited by 558
Self-citationSynthesis of BODIPY dyes through postfunctionalization of the boron dipyrromethene core
Boens, N., Verbelen, B., Ortiz, M. J., Jiao, L., & Dehaen, W. (2019) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2019.213024 · Cited by 396
Chemically diverse small molecule fluorescent chemosensors for copper ion
Sivaraman, G., Iniya, M., Anand, T., Kotla, N. G., Sunnapu, O., Singaravadivel, S., Gulyani, A., & Chellappa, D. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2017.11.020 · Cited by 391
Aron, A. T., Ramos-Torres, K. M., Cotruvo, J. A., & Chang, C. J. (2015) · Accounts of Chemical Research · doi:10.1021/acs.accounts.5b00221 · Cited by 280
Self-citationCyclometalated iridium(III) complexes for life science
Caporale, C., & Massi, M. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2018.02.006 · Cited by 258
Grover, K., Koblova, A., Pezacki, A. T., Chang, C. J., & New, E. J. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00819 · Cited by 129
Self-citation
Metadata
- Authors
- Dodani, S. C., Leary, S. C., Cobine, P. A., Winge, D. R., & Chang, C. J.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-05-12
- Volume
- 133
- Issue
- 22
- Pages
- 8606-8616
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2061159332
- Cited by
- 298
- References
- 8
- FWCI
- 13.13
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.