The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Selective Detection of the Reduced Form of Glutathione (GSH) over the Oxidized (GSSG) Form Using a Combination of Glutathione Reductase and a Tb(III)-Cyclen Maleimide Based Lanthanide Luminescent ‘Switch On’ Assay
Abstract
The synthesis of a novel Tb(III) luminescent probe for the detection of thiols is presented. The probe 1.Tb, possessing a maleimide moiety, as its sulfhydryl acceptor, was poorly emitting in aqueous pH 7 solution in the absence of a thiol. However, upon addition of thiols such as glutathione (GSH), large enhancements were observed, particularly within the physiological pH range. In contrast no enhancements were observed in the presence of the oxidized form of glutathione (GSSG), except in the presence of the enzyme glutathione reductase and NADPH which enabled 1.Tb to be used to observe the enzymatic reduction of GSSG to GSH in real time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Griffith, O. W. (1980) · Analytical Biochemistry · doi:10.1016/0003-2697(80)90139-6 · Cited by 4,602
Lanthanide luminescence for functional materials and bio-sciences
Eliseeva, S. V., & Bünzli, J.-C. G. (2010) · Chem. Soc. Rev. · doi:10.1039/b905604c · Cited by 3,538
Plasma Homocysteine as a Risk Factor for Dementia and Alzheimer's Disease
Seshadri, S., Beiser, A., Selhub, J., Jacques, P. F., Rosenberg, I. H., D'Agostino, R. B., Wilson, P. W. F., & Wolf, P. A. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa011613 · Cited by 3,237
Lanthanide Luminescence for Biomedical Analyses and Imaging
Bünzli, J.-C. G. (2010) · Chemical Reviews · doi:10.1021/cr900362e · Cited by 2,690
Rahman, I., Kode, A., & Biswas, S. K. (2006) · Nature Protocols · doi:10.1038/nprot.2006.378 · Cited by 2,262
Homocysteine and Cardiovascular Disease
Refsum, H., Ueland, P. M., Nygård, O., & Vollset, S. E. (1998) · Annual Review of Medicine · doi:10.1146/annurev.med.49.1.31 · Cited by 2,180
Glutathione metabolism and its selective modification.
Meister, A. (1988) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)77815-6 · Cited by 2,011
Fluorescent and colorimetric probes for detection of thiols
Chen, X., Zhou, Y., Peng, X., & Yoon, J. (2010) · Chemical Society Reviews · doi:10.1039/b925092a · Cited by 1,580
Beeby, A., Clarkson, I. M., Dickins, R. S., Faulkner, S., Parker, D., Royle, L., de Sousa, A. S., Williams, J. A. G., & Woods, M. (1999) · Journal of the Chemical Society, Perkin Transactions 2 · doi:10.1039/a808692c · Cited by 1,447
Lead Phthalocyanine as a Selective Carrier for Preparation of a Cysteine-Selective Electrode
Shahrokhian, S. (2001) · Analytical Chemistry · doi:10.1021/ac010541m · Cited by 1,033
Cited by
Niu, L.-Y., Guan, Y.-S., Chen, Y.-Z., Wu, L.-Z., Tung, C.-H., & Yang, Q.-Z. (2012) · Journal of the American Chemical Society · doi:10.1021/ja309079f · Cited by 901
Recent progress in luminescent and colorimetric chemosensors for detection of thiols
Jung, H. S., Chen, X., Kim, J. S., & Yoon, J. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60024f · Cited by 882
Design strategies of fluorescent probes for selective detection among biothiols
Niu, L.-Y., Chen, Y.-Z., Zheng, H.-R., Wu, L.-Z., Tung, C.-H., & Yang, Q.-Z. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00152h · Cited by 870
Tetraphenylethylene-Based AIE-Active Probes for Sensing Applications
La, D. D., Bhosale, S. V., Jones, L. A., & Bhosale, S. V. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b12320 · Cited by 585
Thiol-addition reactions and their applications in thiol recognition
Yin, C., Huo, F., Zhang, J., Martínez-Máñez, R., Yang, Y., Lv, H., & Li, S. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60055f · Cited by 554
Wu, X., Sun, X., Guo, Z., Tang, J., Shen, Y., James, T. D., Tian, H., & Zhu, W. (2014) · Journal of the American Chemical Society · doi:10.1021/ja412380j · Cited by 539
Gu, K., Xu, Y., Li, H., Guo, Z., Zhu, S., Zhu, S., Shi, P., James, T. D., Tian, H., & Zhu, W.-H. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.6b01705 · Cited by 498
Krämer, J., Kang, R., Grimm, L. M., De Cola, L., Picchetti, P., & Biedermann, F. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00746 · Cited by 449
Guo, Z., Nam, S., Park, S., & Yoon, J. (2012) · Chemical Science · doi:10.1039/c2sc20540h · Cited by 431
A Reversible Fluorescent Probe for Real‐Time Quantitative Monitoring of Cellular Glutathione
Liu, Z., Zhou, X., Miao, Y., Hu, Y., Kwon, N., Wu, X., & Yoon, J. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201702114 · Cited by 312
Lee, S., Li, J., Zhou, X., Yin, J., & Yoon, J. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2018.03.021 · Cited by 300
Covalent Modification of Biomolecules through Maleimide-Based Labeling Strategies
Renault, K., Fredy, J. W., Renard, P.-Y., & Sabot, C. (2018) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.8b00252 · Cited by 262
Metadata
- Authors
- McMahon, B. K., & Gunnlaugsson, T.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-04-02
- Volume
- 134
- Issue
- 26
- Pages
- 10725-10728
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2332928565
- Cited by
- 261
- References
- 38
- FWCI
- 9.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.