The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Target-Responsive “Sweet” Hydrogel with Glucometer Readout for Portable and Quantitative Detection of Non-Glucose Targets
Abstract
Portable devices with the advantages of rapid, on-site, user-friendly, and cost-effective assessment are widely applied in daily life. However, only a limited number of quantitative portable devices are commercially available, among which the personal glucose meter (PGM) is the most successful example and has been the most widely used. However, PGMs can detect only blood glucose as the unique target. Here we describe a novel design that combines a glucoamylase-trapped aptamer-cross-linked hydrogel with a PGM for portable and quantitative detection of non-glucose targets. Upon target introduction, the hydrogel collapses to release glucoamylase, which catalyzes the hydrolysis of amylose to produce a large amount of glucose for quantitative readout by the PGM. With the advantages of low cost, rapidity, portability, and ease of use, the method reported here has the potential to be used by the public for portable and quantitative detection of a wide range of non-glucose targets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Shen, F., Sun, B., Kreutz, J. E., Davydova, E. K., Du, W., Reddy, P. L., Joseph, L. J., & Ismagilov, R. F. (2011) · Journal of the American Chemical Society · doi:10.1021/ja2060116 · Cited by 231
Cited by
Paper Electrode-Based Flexible Pressure Sensor for Point-of-Care Immunoassay with Digital Multimeter
Yu, Z., Tang, Y., Cai, G., Ren, R., & Tang, D. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04635 · Cited by 341
Metadata
- Authors
- Yan, L., Zhu, Z., Zou, Y., Huang, Y., Liu, D., Jia, S., Xu, D., Wu, M., Zhou, Y., Zhou, S., & Yang, C. J.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-01-29
- Volume
- 135
- Issue
- 10
- Pages
- 3748-3751
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2325415030
- Cited by
- 329
- References
- 1
- FWCI
- 13.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Target-Responsive “Sweet” Hydrogel with Glucometer Readout for Portable and Quantitative Detection of Non-Glucose Targets. https://app.cochat.ai/papers/10.1021/ja3114714
- The paper
- Yan, L., Zhu, Z., Zou, Y., Huang, Y., Liu, D., Jia, S., Xu, D., Wu, M., Zhou, Y., Zhou, S., & Yang, C. J. (2013). Target-Responsive “Sweet” Hydrogel with Glucometer Readout for Portable and Quantitative Detection of Non-Glucose Targets. Journal of the American Chemical Society. https://doi.org/10.1021/ja3114714
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.