Paper Electrode-Based Flexible Pressure Sensor for Point-of-Care Immunoassay with Digital Multimeter

Yu, Zhenzhong, Tang, Yun, Cai, Guoneng, Ren, Rongrong, Tang, Dianping·2019·Analytical Chemistry

Abstract

High Resolution Image Download MS PowerPoint Slide A novel paper electrode-based flexible pressure sensor modified with multiwalled carbon nanotubes was designed for point-of-care (POC) immunoassay of carcinoembryonic antigen (CEA) with digital multimeter readout. The portable POC testing device consisted of flexible pressure sensor equipped with a paper electrode and connected through syringe tubing to a single-break microplate. The immunoreaction was initially carried out on the microplate with a sandwich-type assay format using platinum nanozyme-labeled secondary antibody for the gas generation. Upon addition of hydrogen peroxide (H 2 O 2 ), platinum nanozyme (catalase-like mimic) reduced it into hydrogen oxide and oxygen (O 2 ). The overflowing oxygen gas increased the pressure of the multiwalled carbon nanotube-functionalized paper electrode in a homemade pressure-tight system, and the increased pressure could be readily monitored using the paper electrode-based flexible pressure-tight sensor with a digital multimeter readout. The detectable signal mainly derived from the resistance change of pressure sensor because of its deformation with the assistance of the as-generated gas, and the shift in the resistance could be allowed to detect the gas pressure even as low as 80 Pa. Under optimum conditions, pressure sensor-based immunoassay exhibited good resistance responses toward target CEA within a linear range of 0.5–60 ng/mL at a detection limit of 167 pg/mL. Moreover, our strategy provided acceptable reproducibility, precision, high specificity, and good accordance with the commercial CEA ELISA kit for detecting human serum specimens.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.8b04635

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 341

Metadata

Authors
Yu, Z., Tang, Y., Cai, G., Ren, R., & Tang, D.
Venue
Analytical Chemistry
Published
2018-12-20
Volume
91
Issue
2
Pages
1222-1226
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2906408314
Cited by
341
References
18
FWCI
16.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Paper Electrode-Based Flexible Pressure Sensor for Point-of-Care Immunoassay with Digital Multimeter. https://app.cochat.ai/papers/10.1021/acs.analchem.8b04635
The paper
Yu, Z., Tang, Y., Cai, G., Ren, R., & Tang, D. (2019). Paper Electrode-Based Flexible Pressure Sensor for Point-of-Care Immunoassay with Digital Multimeter. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.8b04635

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.