Multiplexed Quantification of Nucleic Acids with Large Dynamic Range Using Multivolume Digital RT-PCR on a Rotational SlipChip Tested with HIV and Hepatitis C Viral Load

Open access
Shen, Feng, Sun, Bing, Kreutz, Jason E., Davydova, Elena K., Du, Wenbin, Reddy, Poluru L., Joseph, Loren J., Ismagilov, Rustem F.·2011·Journal of the American Chemical Society

Abstract

In this paper, we are working toward a problem of great importance to global health: determination of viral HIV and hepatitis C (HCV) loads under point-of-care and resource limited settings. While antiretroviral treatments are becoming widely available, viral load must be evaluated at regular intervals to prevent the spread of drug resistance and requires a quantitative measurement of RNA concentration over a wide dynamic range (from 50 up to 10(6) molecules/mL for HIV and up to 10(8) molecules/mL for HCV). "Digital" single molecule measurements are attractive for quantification, but the dynamic range of such systems is typically limited or requires excessive numbers of compartments. Here we designed and tested two microfluidic rotational SlipChips to perform multivolume digital RT-PCR (MV digital RT-PCR) experiments with large and tunable dynamic range. These designs were characterized using synthetic control RNA and validated with HIV viral RNA and HCV control viral RNA. The first design contained 160 wells of each of four volumes (125 nL, 25 nL, 5 nL, and 1 nL) to achieve a dynamic range of 5.2 × 10(2) to 4.0 × 10(6) molecules/mL at 3-fold resolution. The second design tested the flexibility of this approach, and further expanded it to allow for multiplexing while maintaining a large dynamic range by adding additional wells with volumes of 0.2 nL and 625 nL and dividing the SlipChip into five regions to analyze five samples each at a dynamic range of 1.8 × 10(3) to 1.2 × 10(7) molecules/mL at 3-fold resolution. No evidence of cross-contamination was observed. The multiplexed SlipChip can be used to analyze a single sample at a dynamic range of 1.7 × 10(2) to 2.0 × 10(7) molecules/mL at 3-fold resolution with limit of detection of 40 molecules/mL. HIV viral RNA purified from clinical samples were tested on the SlipChip, and viral load results were self-consistent and in good agreement with results determined using the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 Test. With further validation, this SlipChip should become useful to precisely quantify viral HIV and HCV RNA for high-performance diagnostics in resource-limited settings. These microfluidic designs should also be valuable for other diagnostic and research applications, including detecting rare cells and rare mutations, prenatal diagnostics, monitoring residual disease, and quantifying copy number variation and gene expression patterns. The theory for the design and analysis of multivolume digital PCR experiments is presented in other work by Kreutz et al.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ja2060116

Cites

61 of 61 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

1 of the 62 references couldn’t be matched to a known paper.

Research works printed but not linked: 2

  1. [21]Sykes PJ Neoh SH Brisco MJ Hughes E Condon J Morley AA Biotechniques 1992 13 444 449 1389177
  2. [37]Destgroth SF J Immunol Methods 1982 49 R11 R23 7040548

Cited by

Sorted by citations

Authors
Shen, F., Sun, B., Kreutz, J. E., Davydova, E. K., Du, W., Reddy, P. L., Joseph, L. J., & Ismagilov, R. F.
Affiliations
  • University of Chicago (US)
  • University of Chicago Medical Center (US)
Corresponding author
Ismagilov, Rustem F.
Venue
Journal of the American Chemical Society
Published
2011-10-13
Volume
133
Issue
44
Pages
17705-17712
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W1979899105
Cited by
231
References
62
Citations by year
2026: 8 · 2025: 11 · 2024: 13 · 2023: 8 · 2022: 18 · 2021: 14 · 2020: 19 · 2019: 19 · 2018: 17 · 2017: 18 · 2016: 23 · 2015: 8 · 2014: 25 · 2013: 18 · 2012: 11
FWCI
10.43
Type
journal article
Language
en
Open access
Locations
  • Journal of the American Chemical Society (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
  • CaltechAUTHORS (California Institute of Technology) (submittedVersion)
Funders
  • National Institutes of Health (DP1OD003584)
  • National Institute of Biomedical Imaging and Bioengineering (R01EB012946)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications
Keywords
SlipChip, HIV viral load, wide dynamic range, point-of-care testing, resource-limited settings, single-molecule detection, viral RNA quantification, detection limit, HIV-1 RNA, HCV RNA, cross-contamination, antimicrobial resistance surveillance
MeSH terms
HIV, RNA, Viral, Rotation, Hepacivirus, Viral Load, Reverse Transcriptase Polymerase Chain Reaction, Microfluidic Analytical Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review