Single Particle Detection by Area Amplification: Single Wall Carbon Nanotube Attachment to a Nanoelectrode
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We describe the electrochemical detection of single nanoparticle (NP) attachment on a nanoelectrode by the increase in the active electrode area. The attachment of gold NP-decorated single wall carbon nanotubes (Au-SWCNTs) was observed by their current-time transients for ferrocenemethanol (FcMeOH) oxidation. Since the attached Au-SWCNT increases the electroactive area available for FcMeOH oxidation, the current increases after attachment of the particle. The "staircase" shape of the current response establishes that the particles do not become deactivated for the outer-sphere electron transfer reaction after attachment. Au-SWCNTs migrate to and are held at the nanoelectrode by an electric field. However, SWCNTs that are not decorated with a gold NP produce only a sharp transient ("blip") response.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Arenz, M., Mayrhofer, K. J. J., Stamenkovic, V., Blizanac, B. B., Tomoyuki, T., Ross, P. N., & Markovic, N. M. (2005) · Journal of the American Chemical Society · doi:10.1021/ja043602h · Cited by 556
Time-Resolved Electrochemical Detection of Discrete Adsorption Events
Quinn, B. M., van't Hof, P. G., & Lemay, S. G. (2004) · Journal of the American Chemical Society · doi:10.1021/ja0478577 · Cited by 274
Cited by
Label-Free Detection of Single Living Bacteria via Electrochemical Collision Event
Lee, J. Y., Kim, B.-K., Kang, M., & Park, J. H. (2016) · Scientific Reports · doi:10.1038/srep30022 · Cited by 91
Self-citationReview—Electrochemistry's Potential to Reach the Ultimate Sensitivity in Measurement Science
Goines, S., & Dick, J. E. (2020) · Journal of The Electrochemical Society · doi:10.1149/2.0052003jes · Cited by 81
Single-entity electrochemistry of collision in sensing applications
Sekretareva, A. (2021) · Sensors and Actuators Reports · doi:10.1016/j.snr.2021.100037 · Cited by 41
Metadata
- Authors
- Park, J. H., Thorgaard, S. N., Zhang, B., & Bard, A. J.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-04-02
- Volume
- 135
- Issue
- 14
- Pages
- 5258-5261
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2330782041
- Cited by
- 99
- References
- 2
- FWCI
- 7.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Single Particle Detection by Area Amplification: Single Wall Carbon Nanotube Attachment to a Nanoelectrode. https://app.cochat.ai/papers/10.1021/ja4000917
- The paper
- Park, J. H., Thorgaard, S. N., Zhang, B., & Bard, A. J. (2013). Single Particle Detection by Area Amplification: Single Wall Carbon Nanotube Attachment to a Nanoelectrode. Journal of the American Chemical Society. https://doi.org/10.1021/ja4000917
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.