Cited by 275Electrochemical Analysis and ApplicationsElectrochemical sensors and biosensorsAdvanced biosensing and bioanalysis techniques

Time-Resolved Electrochemical Detection of Discrete Adsorption Events

Quinn, Bernadette M., van't Hof, Pieter G., Lemay, Serge G.·2004·Journal of the American Chemical Society

Abstract

Individual binding events are observed using amperometric detection. Discrete steps in the microelectrode amperometric response correspond to the adsorption of single microspheres on the electrode surface.

Integrity signals

Registry

Crossref · 10.1021/ja0478577

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The blocking collisions method was initially reported by Quinn et al. for the detection of insulating polystyrene beads (1 μm diameter) onto an Au microelectrode disk (5 μm diameter) in hydroxymethylferrocene aqueous solution.

    “The blocking collisions method is initially reported by Quinn et al. for the detection of insulating polystyrene beads (1 µm diameter) onto an Au microelectrode disk (5 µm diameter) in a hydroxymethylferrocene (ferrocenemethanol) aqueous solution [21].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Quinn, B. M., van't Hof, P. G., & Lemay, S. G.
Affiliations
  • Delft University of Technology (NL)
  • Kavli Institute of Nanoscience, Delft University of Technology, Lorentzweg 1, 2628 CJ Delft, The Netherlands
Corresponding author
Lemay, Serge G.
Venue
Journal of the American Chemical Society
Published
2004-06-17
Volume
126
Issue
27
Pages
8360-8361
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W2080075646
Cited by
274
References
12
Citations by year
2026: 8 · 2025: 13 · 2024: 25 · 2023: 28 · 2022: 19 · 2021: 24 · 2020: 26 · 2019: 25 · 2018: 32 · 2017: 15 · 2016: 27 · 2015: 12 · 2014: 12 · 2013: 5 · 2012: 1
FWCI
0.53
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of the American Chemical Society (publishedVersion)
  • PubMed (publishedVersion)
Funders
Nederlandse Organisatie voor Wetenschappelijk Onderzoek
Topics
  • Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
Keywords
amperometric detection, microelectrodes

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review