The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A “Turn-On” Fluorescent Sensor for Methylglyoxal
Abstract
Methylglyoxal (MGO), a dicarbonyl metabolite produced by all living cells, has been associated with a number of human diseases. However, studies of the role(s) MGO plays biologically have been handicapped by a lack of direct methods for its monitoring and detection. To address this limitation, we have developed a fluorescent sensor (methyl diaminobenzene-BODIPY, or "MBo") that can detect MGO under physiological conditions. We show that MBo is selective for MGO over other biologically relevant dicarbonyls and is suitable for detecting MGO in complex environments, including that of living cells. In addition, we demonstrate MBo's utility in estimating plasma concentrations of MGO. The results reported herein have the potential to advance both clinical and basic science research and practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advanced glycation end-products: A review
Singh, R., Barden, A., Mori, T., & Beilin, L. (2001) · Diabetologia · doi:10.1007/s001250051591 · Cited by 2,597
Ignarro, L. J., Lippton, H., Edwards, J. C., Baricos, W. H., Hyman, A. L., Kadowitz, P. J., & Gruetter, C. A. (1981) · The Journal of Pharmacology and Experimental Therapeutics · doi:10.1016/s0022-3565(25)32738-2 · Cited by 1,633
What is the real physiological NO concentration in vivo?
Hall, C. N., & Garthwaite, J. (2009) · Nitric Oxide · doi:10.1016/j.niox.2009.07.002 · Cited by 378
Cited by
BODIPY-based probes for the fluorescence imaging of biomolecules in living cells
Kowada, T., Maeda, H., & Kikuchi, K. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00030k · Cited by 1,381
Sánchez-Carnerero, E. M., Moreno, F., Maroto, B. L., Agarrabeitia, A. R., Ortiz, M. J., Vo, B. G., Muller, G., & Moya, S. D. L. (2014) · Journal of the American Chemical Society · doi:10.1021/ja412294s · Cited by 410
Redox Signaling by Reactive Electrophiles and Oxidants
Parvez, S., Long, M. J. C., Poganik, J. R., & Aye, Y. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00698 · Cited by 359
Dual-locked spectroscopic probes for sensing and therapy
Wu, L., Huang, J., Pu, K., & James, T. D. (2021) · Nature Reviews Chemistry · doi:10.1038/s41570-021-00277-2 · Cited by 328
An Aza-Cope Reactivity-Based Fluorescent Probe for Imaging Formaldehyde in Living Cells
Brewer, T. F., & Chang, C. J. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b05340 · Cited by 271
Metadata
- Authors
- Wang, T., Douglass, E. F., Fitzgerald, K. J., & Spiegel, D. A.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-08-09
- Volume
- 135
- Issue
- 33
- Pages
- 12429-12433
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2324888199
- Cited by
- 195
- References
- 3
- FWCI
- 6.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A “Turn-On” Fluorescent Sensor for Methylglyoxal. https://app.cochat.ai/papers/10.1021/ja406077j
- The paper
- Wang, T., Douglass, E. F., Fitzgerald, K. J., & Spiegel, D. A. (2013). A “Turn-On” Fluorescent Sensor for Methylglyoxal. Journal of the American Chemical Society. https://doi.org/10.1021/ja406077j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.