Electrogenerated Chemiluminescence of Common Organic Luminophores in Water Using an Emulsion System
The DOI matches its Crossref record.
Abstract
We describe a method to produce electrogenerated chemiluminescence (ECL) in water using a family of highly hydrophobic polycyclic aromatic hydrocarbon (PAH) luminophores and boron dipyrromethene (BODIPY). This method is based on an oil-in-water emulsion system. Various PAHs (rubrene, 9,10-diphenylanthracene, pyrene, or perylene) and BODIPY were trapped in a toluene and tri-n-propylamine mixed oil-in-water emulsion using an ionic liquid as the supporting electrolyte and emulsifier. ECL was observed for all the aforementioned PAHs and BODIPY, and the rubrene and BODIPY emulsion systems showed adequate light to record an ECL spectrum. ECL was also observed using oxalate as the co-reactant, which was dissolved in the aqueous continuous phase. The emulsions were stable for hours and showed a droplet size distribution that ranged from 275 to 764 nm, in accordance with dynamic light scattering data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dick, J. E., Hilterbrand, A. T., Boika, A., Upton, J. W., & Bard, A. J. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1504294112 · Cited by 166
“Relatively arduous techniques, with varying degrees of sensitivity, exist for the detection of pathogens, including ELISA methods, sensitive PCR techniques, culturing, ECL, and microscopy.”
BackgroundInfluentialSelf-citationElectrochemical Detection of Single Phospholipid Vesicle Collisions at a Pt Ultramicroelectrode
Lebègue, E., Anderson, C. M., Dick, J. E., Webb, L. J., & Bard, A. J. (2015) · Langmuir · doi:10.1021/acs.langmuir.5b03123 · Cited by 137
Self-citationReview—Electrochemistry's Potential to Reach the Ultimate Sensitivity in Measurement Science
Goines, S., & Dick, J. E. (2020) · Journal of The Electrochemical Society · doi:10.1149/2.0052003jes · Cited by 81
Self-citationMillisecond Coulometry via Zeptoliter Droplet Collisions on an Ultramicroelectrode
Dick, J. E., Lebègue, E., Strawsine, L. M., & Bard, A. J. (2016) · Electroanalysis · doi:10.1002/elan.201600182 · Cited by 46
Self-citation
Metadata
- Authors
- Dick, J. E., Renault, C., Kim, B.-K., & Bard, A. J.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-09-19
- Volume
- 136
- Issue
- 39
- Pages
- 13546-13549
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2056332543
- Cited by
- 114
- References
- 0
- FWCI
- 4.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrogenerated Chemiluminescence of Common Organic Luminophores in Water Using an Emulsion System. https://app.cochat.ai/papers/10.1021/ja507198r
- The paper
- Dick, J. E., Renault, C., Kim, B.-K., & Bard, A. J. (2014). Electrogenerated Chemiluminescence of Common Organic Luminophores in Water Using an Emulsion System. Journal of the American Chemical Society. https://doi.org/10.1021/ja507198r
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.