Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 2,282

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Liquid Phase Production of Graphene by Exfoliation of Graphite in Surfactant/Water Solutions

Lotya, Mustafa, Hernandez, Yenny, King, Paul J., Smith, Ronan J., Nicolosi, Valeria, Karlsson, Lisa S., Blighe, Fiona M., De, Sukanta, Wang, Zhiming, McGovern, I. T., Duesberg, Georg S., Coleman, Jonathan N.·2009·Journal of the American Chemical Society

Abstract

We have demonstrated a method to disperse and exfoliate graphite to give graphene suspended in water-surfactant solutions. Optical characterization of these suspensions allowed the partial optimization of the dispersion process. Transmission electron microscopy showed the dispersed phase to consist of small graphitic flakes. More than 40% of these flakes had <5 layers with approximately 3% of flakes consisting of monolayers. Atomic resolution transmission electron microscopy shows the monolayers to be generally free of defects. The dispersed graphitic flakes are stabilized against reaggregation by Coulomb repulsion due to the adsorbed surfactant. We use DLVO and Hamaker theory to describe this stabilization. However, the larger flakes tend to sediment out over approximately 6 weeks, leaving only small flakes dispersed. It is possible to form thin films by vacuum filtration of these dispersions. Raman and IR spectroscopic analysis of these films suggests the flakes to be largely free of defects and oxides, although X-ray photoelectron spectroscopy shows evidence of a small oxide population. Individual graphene flakes can be deposited onto mica by spray coating, allowing statistical analysis of flake size and thickness. Vacuum filtered films are reasonably conductive and are semitransparent. Further improvements may result in the development of cheap transparent conductors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ja807449u

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 30 references

Research works printed but not linked: 9

  1. Ohta T., 2008, New J. Phys., 10
  2. Bergin S. D., 2008, J. Phys. Chem. C, 112, 972, 10.1021/jp076915i · doi:10.1021/jp076915i
  3. Abergel D. S. L., 2007, Phys. Rev. B, 75
  4. Lockwood N. A., 2005, Langmuir, 21, 6805, 10.1021/la050231p · doi:10.1021/la050231p
  5. McDonald T. J., 2006, J. Phys. Chem. B, 110, 25339, 10.1021/jp065281x · doi:10.1021/jp065281x
  6. Michov B. M., 1988, Electrophoresis, 9, 199, 10.1002/elps.1150090409 · doi:10.1002/elps.1150090409
  7. Atkins P. W., 1990, Physical Chemistry
  8. Nicolosi V., 2005, J. Phys. Chem. B, 109, 7124, 10.1021/jp045166r · doi:10.1021/jp045166r
  9. Ferrari A. C., 2006, Phys. Rev. Lett., 97

Cited by

Items 101–200 of 209

Metadata

Authors
Lotya, M., Hernandez, Y., King, P. J., Smith, R. J., Nicolosi, V., Karlsson, L. S., Blighe, F. M., De, S., Wang, Z., McGovern, I. T., Duesberg, G. S., & Coleman, J. N.
Venue
Journal of the American Chemical Society
Published
2009-02-19
Volume
131
Issue
10
Pages
3611-3620
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W2020306845
Cited by
2,282
References
30
FWCI
59.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.