The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Photoswitching Mechanism of Cyanine Dyes
Open accessAbstract
Cyanine dyes have been shown to undergo reversible photoswitching, where the fluorophore can be switched between a fluorescent state and a dark state upon illumination at different wavelengths. The photochemical mechanism by which switching occurs has yet to be elucidated. In this study, we have determined the mechanism of photoswitching by characterizing the kinetics of dark state formation and the spectral and structural properties of the dark state. The rate of switching to the dark state depends on the concentration of the primary thiol in the solution and the solution pH in a manner quantitatively consistent with the formation of an encounter complex between the cyanine dye and ionized thiol prior to their conjugation. Mass spectrometry suggests that the photoconversion product is a thiol-cyanine adduct in which covalent attachment of the thiol to the polymethine bridge disrupts the original conjugated pi-electron system of the dye.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078
Self-citationUltra-High Resolution Imaging by Fluorescence Photoactivation Localization Microscopy
Hess, S. T., Girirajan, T. P. K., & Mason, M. D. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.091116 · Cited by 3,605
Multicolor Super-Resolution Imaging with Photo-Switchable Fluorescent Probes
Bates, M., Huang, B., Dempsey, G. T., & Zhuang, X. (2007) · Science · doi:10.1126/science.1146598 · Cited by 1,504
Self-citationFluorescent probes for super-resolution imaging in living cells
Fernández-Suárez, M., & Ting, A. Y. (2008) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2531 · Cited by 1,306
Nonblinking and long-lasting single-molecule fluorescence imaging
Rasnik, I., McKinney, S. A., & Ha, T. (2006) · Nature Methods · doi:10.1038/nmeth934 · Cited by 702
Carbocyanine Dyes as Efficient Reversible Single-Molecule Optical Switch
Heilemann, M., Margeat, E., Kasper, R., Sauer, M., & Tinnefeld, P. (2005) · Journal of the American Chemical Society · doi:10.1021/ja044686x · Cited by 406
Short-Range Spectroscopic Ruler Based on a Single-Molecule Optical Switch
Bates, M., Blosser, T. R., & Zhuang, X. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.108101 · Cited by 364
Self-citationProblems and Possibilities of the Free‐Radical Addition of Thiols to Unsaturated Compounds
Griesbaum, K. (1970) · Angewandte Chemie International Edition in English · doi:10.1002/anie.197002731 · Cited by 357
Photochromic Rhodamines Provide Nanoscopy with Optical Sectioning
Fölling, J., Belov, V., Kunetsky, R., Medda, R., Schönle, A., Egner, A., Eggeling, C., Bossi, M., & Hell, S. W. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200702167 · Cited by 291
A Photoactivatable Push−Pull Fluorophore for Single-Molecule Imaging in Live Cells
Lord, S. J., Conley, N. R., Lee, H.-L. D., Samuel, R., Liu, N., Twieg, R. J., & Moerner, W. E. (2008) · Journal of the American Chemical Society · doi:10.1021/ja802883k · Cited by 216
Super-resolution microscopy by nanoscale localization of photo-switchable fluorescent probes
Bates, M., Huang, B., & Zhuang, X. (2008) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2008.08.008 · Cited by 208
Self-citationBlue Light Perception in Plants
Kay, C. W. M., Schleicher, E., Kuppig, A., Hofner, H., Rüdiger, W., Schleicher, M., Fischer, M. J., Bacher, A., Weber, S., & Richter, G. (2003) · Journal of Biological Chemistry · doi:10.1074/jbc.m205509200 · Cited by 120
Sabanayagam, C. R., Eid, J. S., & MELLER, A. (2005) · The Journal of Chemical Physics · doi:10.1063/1.2136157 · Cited by 84
Cited by
Carbon Nanomaterials for Biological Imaging and Nanomedicinal Therapy
Hong, G., Diao, S., Antaris, A. L., & Dai, H. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00008 · Cited by 1,394
Evaluation of fluorophores for optimal performance in localization-based super-resolution imaging
Dempsey, G. T., Vaughan, J. C., Chen, K. H., Bates, M., & Zhuang, X. (2011) · Nature Methods · doi:10.1038/nmeth.1768 · Cited by 1,369
Self-citationDirect stochastic optical reconstruction microscopy with standard fluorescent probes
van de Linde, S., Löschberger, A., Klein, T., Heidbreder, M., Wolter, S., Heilemann, M., & Sauer, M. (2011) · Nature Protocols · doi:10.1038/nprot.2011.336 · Cited by 1,071
Fast, three-dimensional super-resolution imaging of live cells
Jones, S. A., Shim, S.-H., He, J., & Zhuang, X. (2011) · Nature Methods · doi:10.1038/nmeth.1605 · Cited by 752
Self-citationZhou, J., Yang, Y., & Zhang, C.-Y. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00049 · Cited by 704
Metadata
- Authors
- Dempsey, G. T., Bates, M., Kowtoniuk, W. E., Liu, D. R., Tsien, R. Y., & Zhuang, X.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-12-04
- Volume
- 131
- Issue
- 51
- Pages
- 18192-18193
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2039427568
- Cited by
- 380
- References
- 14
- FWCI
- 8.61
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.