The DOI matches its Crossref record.
Stability of Oxidases Immobilized in Silica Gels
Abstract
The gain or loss of stability of three flavoprotein oxidases, glucose oxidase, lactate oxidase, and glycolate oxidase, upon immobilization in a hydrated silica gel by a sol−gel process was quantified. Glucose oxidase (isoelectric point, IP, pH 3.8) retained most or all of its initial activity, while lactate oxidase and glycolate lost most of theirs. The half-life of glucose oxidase at 63 °C increased upon immobilization 200-fold; the half-lives of lactate oxidase and of glycolate oxidase were not extended beyond those of the water-dissolved enzymes. After lactate oxidase (IP pH 4.6) was electrostatically complexed with the weak base poly( N -vinylimidazole) prior to its immobilization, most of its activity was retained and its half-life at 63° C increased 150-fold. Lactate oxidase was also stabilized when electrostatically complexed with the stronger base poly(ethyleneimine) prior to immobilization. Glycolate oxidase (IP pH 9.6) was not stabilized by poly( N -vinylimidazole) but was stabilized by poly(ethyleneimine) complexing prior to immobilization. The complexed enzyme retained its initial activity upon immobilization, and its half-life at 60 °C also increased 100-fold. The results show that encaging an oxidase in a silica gel can lead either to gain in stability or to loss of activity and that electrostatic complexing is required for stabilization by encapsulation of some, but not all, flavoprotein oxidases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660
Bio-doped Nanocomposite Polymers: Sol−Gel Bioencapsulates
Gill, I. (2001) · Chemistry of Materials · doi:10.1021/cm0102483 · Cited by 393
The sol-gel encapsulation of enzymes
Pierre, A. C. (2004) · Biocatalysis and Biotransformation · doi:10.1080/10242420412331283314 · Cited by 384
Unnikrishnan, B., Palanisamy, S., & Chen, S.-M. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.06.045 · Cited by 358
Encapsulation of biomolecules in silica gels
Livage, J., Coradin, T., & Roux, C. (2001) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/13/33/202 · Cited by 321
Walcarius, A., Mandler, D., Cox, J. A., Collinson, M., & Lev, O. (2005) · Journal of Materials Chemistry · doi:10.1039/b504839g · Cited by 275
A contact lens with an integrated lactate sensor
Thomas, N., Lähdesmäki, I., & Parviz, B. A. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.12.049 · Cited by 220
Implanted Electrochemical Glucose Sensors for the Management of Diabetes
Heller, A. (1999) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.1.1.153 · Cited by 215
Self-citationMesostructured Silica for Optical Functionality, Nanomachines, and Drug Delivery
Klichko, Y., Liong, M., Choi, E., Angelos, S., Nel, A. E., Stoddart, J. F., Tamanoi, F., & Zink, J. I. (2009) · Journal of the American Ceramic Society · doi:10.1111/j.1551-2916.2008.02722.x · Cited by 116
Metadata
- Authors
- Chen, Q., Kenausis, G. L., & Heller, A.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-05-01
- Volume
- 120
- Issue
- 19
- Pages
- 4582-4585
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2001517573
- Cited by
- 168
- References
- 0
- FWCI
- 2.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.