The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Top Down versus Bottom Up Protein Characterization by Tandem High-Resolution Mass Spectrometry
Abstract
Characterization of larger proteins by mass spectrometry (MS) is especially promising because the information complements that of classical techniques and can be obtained on as little as 10 - 17 mol of protein. Using MS to localize errors in the DNA-derived sequence or modifications (posttranslational, derivatized active sites, etc.) usually involves extensive proteolysis to yield peptides of <3 kDa, with separation and MS/MS to compare their sequences to those expected (the “bottom up” approach). In contrast, an alternative “top down” approach limits the dissociation (proteolysis or MS/MS) to yield larger products from which a small set of complementary peptides can be found whose masses sum to those of the molecule. Thus a disagreement with the predicted molecular mass can be localized to a fragment(s) without examining all others, with further dissociation of the fragments in the same way providing further localization. Using carbonic anhydrase (29 kDa) as an example, Fourier transform mass spectrometry is unusually effective for the bottom up approach, in that a single spectrum of an extensive chymotryptic digest identifies 64 expected peptides, but these only cover 95% of the sequence; 20 fragment masses are unassigned so that any set whose masses sum to that of the molecule would be misleading. Extensive Lys-C dissociation yields 17 peptides, 23 unassigned masses, and 96% coverage. In the contrasting “top down” approach, less extensive initial dissociation by Lys-C, MS/MS, or CNBr in each case provides 100% coverage, so that modified protein fragment(s) could easily be recognized among the complementary sets. MS/MS of such a fragment or more extensive proteolysis provide further localization of the modification. The combined methods cleaved 137 of the 258 amide bonds between residues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Electron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881
Self-citationShevchenko, A., Jensen, O. N., Podtelejnikov, A. V., Sagliocco, F., Wilm, M., Vorm, O., Mortensen, P., Shevchenko, A., Boucherie, H., & Mann, M. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.25.14440 · Cited by 1,427
Int. J. Mass Spectrom. Ion Processes
(1990) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(90)80022-u · Cited by 1,003
Gauthier, J. W., Trautman, T. R., & Jacobson, D. B. (1991) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)80678-9 · Cited by 645
Tailored excitation for Fourier transform ion cyclotron mass spectrometry
Marshall, A. G., Wang, T. C. L., & Ricca, T. L. (1985) · Journal of the American Chemical Society · doi:10.1021/ja00312a015 · Cited by 631
Keil, B. (1992) · Springer eBooks · doi:10.1007/978-3-642-48380-6 · Cited by 412
Attomole Protein Characterization by Capillary Electrophoresis-Mass Spectrometry
Valaskovic, G. A., Kelleher, N. L., & McLafferty, F. W. (1996) · Science · doi:10.1126/science.273.5279.1199 · Cited by 398
Self-citationPostseismic Rebound in Fault Step-Overs Caused by Pore Fluid Flow
Peltzer, G., Rosen, P., Rogez, F., & Hudnut, K. (1996) · Science · doi:10.1126/science.273.5279.1202 · Cited by 290
Mørtz, E., O'Connor, P. B., Roepstorff, P., Kelleher, N. L., Wood, T. D., McLafferty, F. W., & Mann, M. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.16.8264 · Cited by 220
Self-citation
Cited by
A Statistical Model for Identifying Proteins by Tandem Mass Spectrometry
Nesvizhskii, A. I., Keller, A., Kolker, E., & Aebersold, R. (2003) · Analytical Chemistry · doi:10.1021/ac0341261 · Cited by 4,809
Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
Definitions of terms relating to mass spectrometry (IUPAC Recommendations 2013)
Murray, K. K., Boyd, R. K., Eberlin, M. N., Langley, G. J., Li, L., & Naito, Y. (2013) · Pure and Applied Chemistry · doi:10.1351/pac-rec-06-04-06 · Cited by 687
Sinz, A. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20082 · Cited by 648
Progress in Top-Down Proteomics and the Analysis of Proteoforms
Toby, T. K., Fornelli, L., & Kelleher, N. L. (2016) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071015-041550 · Cited by 576
Self-citationAutomated reduction and interpretation of
Horn, D. M., Zubarev, R. A., & McLafferty, F. W. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00157-9 · Cited by 507
Self-citationDecoding protein modifications using top-down mass spectrometry
Siuti, N., & Kelleher, N. L. (2007) · Nature Methods · doi:10.1038/nmeth1097 · Cited by 503
Self-citationAnalytical strategies for LC–MS-based targeted metabolomics
Lu, W., Bennett, B. D., & Rabinowitz, J. D. (2008) · Journal of Chromatography B · doi:10.1016/j.jchromb.2008.04.031 · Cited by 481
Proteomics by FTICR mass spectrometry: Top down and bottom up
Bogdanov, B., & Smith, R. D. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20015 · Cited by 447
Best practices and benchmarks for intact protein analysis for top-down mass spectrometry
Donnelly, D. P., Rawlins, C. M., DeHart, C. J., Fornelli, L., Schachner, L. F., Lin, Z., Lippens, J. L., Aluri, K. C., Sarin, R., Chen, B., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0457-0 · Cited by 377
Self-citationComplete Protein Characterization Using Top-Down Mass Spectrometry and Ultraviolet Photodissociation
Shaw, J. B., Li, W., Holden, D. D., Zhang, Y., Griep-Raming, J., Fellers, R. T., Early, B. P., Thomas, P. M., Kelleher, N. L., & Brodbelt, J. S. (2013) · Journal of the American Chemical Society · doi:10.1021/ja4029654 · Cited by 371
Self-citationProbing protein structure by amino acid‐specific covalent labeling and mass spectrometry
Mendoza, V. L., & Vachet, R. W. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20203 · Cited by 364
Extending Top-Down Mass Spectrometry to Proteins with Masses Greater Than 200 Kilodaltons
Han, X., Jin, M., Breuker, K., & McLafferty, F. W. (2006) · Science · doi:10.1126/science.1128868 · Cited by 328
Self-citationTerminology of bioanalytical methods (IUPAC Recommendations 2018)
Labuda, J., Bowater, R. P., Fojta, M., Gauglitz, G., Glatz, Z., Hapala, I., Havliš, J., Kilar, F., Kilar, A., Malinovská, L., et al. (2018) · Pure and Applied Chemistry · doi:10.1515/pac-2016-1120 · Cited by 287
‘Top down’ protein characterization via tandem mass spectrometry
Reid, G. E., & McLuckey, S. A. (2002) · Journal of Mass Spectrometry · doi:10.1002/jms.346 · Cited by 285
Martin, S. E., Shabanowitz, J., Hunt, D. F., & Marto, J. A. (2000) · Analytical Chemistry · doi:10.1021/ac000497v · Cited by 276
Top‐down proteomics in health and disease: Challenges and opportunities
Gregorich, Z. R., & Ge, Y. (2014) · PROTEOMICS · doi:10.1002/pmic.201300432 · Cited by 217
The diverse and expanding role of mass spectrometry in structural and molecular biology
Lössl, P., van de Waterbeemd, M., & Heck, A. J. (2016) · The EMBO Journal · doi:10.15252/embj.201694818 · Cited by 222
Tran, J. C., & Doucette, A. A. (2008) · Analytical Chemistry · doi:10.1021/ac702197w · Cited by 206
Zhang, J., Guy, M. J., Norman, H. S., Chen, Y.-C., Xu, Q., Dong, X., Guner, H., Wang, S., Kohmoto, T., Young, K. H., et al. (2011) · Journal of Proteome Research · doi:10.1021/pr200258m · Cited by 194
Processing Complex Mixtures of Intact Proteins for Direct Analysis by Mass Spectrometry
Meng, F., Cargile, B. J., Patrie, S. M., Johnson, J. R., McLoughlin, S. M., & Kelleher, N. L. (2002) · Analytical Chemistry · doi:10.1021/ac020049i · Cited by 183
Self-citationProteins in Art, Archaeology, and Paleontology: From Detection to Identification
Dallongeville, S., Garnier, N., Rolando, C., & Tokarski, C. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00037 · Cited by 172
Roberts, D. S., Loo, J. A., Tsybin, Y. O., Liu, X., Wu, S., Chamot-Rooke, J., Agar, J. N., Paša-Tolić, L., Smith, L. M., & Ge, Y. (2024) · Nature Reviews Methods Primers · doi:10.1038/s43586-024-00318-2 · Cited by 161
Ge, Y., Rybakova, I. N., Xu, Q., & Moss, R. L. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0813369106 · Cited by 154
Lermyte, F., Tsybin, Y. O., O’Connor, P. B., & Loo, J. A. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02201-x · Cited by 132
McCool, E. N., Lubeckyj, R. A., Shen, X., Chen, D., Kou, Q., Liu, X., & Sun, L. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00693 · Cited by 117
Peng, Y., Gregorich, Z. R., Valeja, S. G., Zhang, H., Cai, W., Chen, Y.-C., Guner, H., Chen, A. J., Schwahn, D. J., Hacker, T. A., et al. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m114.040675 · Cited by 107
Augmented Phosphorylation of Cardiac Troponin I in Hypertensive Heart Failure
Dong, X., Sumandea, C. A., Chen, Y.-C., Garcia-Cazarin, M. L., Zhang, J., Balke, C. W., Sumandea, M. P., & Ge, Y. (2012) · Journal of Biological Chemistry · doi:10.1074/jbc.m111.293258 · Cited by 99
Kellie, J. F., Tran, J. C., Lee, J. E., Ahlf, D. R., Thomas, H. M., Ntai, I., Catherman, A. D., Durbin, K. R., Zamdborg, L., Vellaichamy, A., et al. (2010) · Molecular BioSystems · doi:10.1039/c000896f · Cited by 99
Self-citationMazur, M. T., Cardasis, H. L., Spellman, D. S., Liaw, A., Yates, N. A., & Hendrickson, R. C. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910776107 · Cited by 87
Han, X., Wang, Y., Aslanian, A., Bern, M., Lavallée-Adam, M., & Yates, J. R. (2014) · Analytical Chemistry · doi:10.1021/ac503439n · Cited by 77
Han, X., Wang, Y., Aslanian, A., Fonslow, B., Graczyk, B., Davis, T. N., & Yates, J. R. (2014) · Journal of Proteome Research · doi:10.1021/pr500971h · Cited by 72
ClipsMS: An Algorithm for Analyzing Internal Fragments Resulting from Top-Down Mass Spectrometry
(2021) · doi:10.1021/acs.jproteome.0c00952 · Cited by 72
Zhao, Y., Sun, L., Zhu, G., & Dovichi, N. J. (2016) · Journal of Proteome Research · doi:10.1021/acs.jproteome.6b00493 · Cited by 61
Zhao, Y., Sun, L., Champion, M. M., Knierman, M. D., & Dovichi, N. J. (2014) · Analytical Chemistry · doi:10.1021/ac500092q · Cited by 56
Konijnenberg, A., Bannwarth, L., Yilmaz, D., Koçer, A., Venien‐Bryan, C., & Sobott, F. (2015) · Protein Science · doi:10.1002/pro.2703 · Cited by 45
The benefits (and misfortunes) of SDS in top-down proteomics
Kachuk, C., & Doucette, A. A. (2018) · Journal of Proteomics · doi:10.1016/j.jprot.2017.03.002 · Cited by 39
Fragmentation of Integral Membrane Proteins in the Gas Phase
Skinner, O. S., Catherman, A. D., Early, B. P., Thomas, P. M., Compton, P. D., & Kelleher, N. L. (2014) · Analytical Chemistry · doi:10.1021/ac500864w · Cited by 29
Self-citationLakshmanan, R., Wolff, J. J., Alvarado, R., & Loo, J. A. (2014) · PROTEOMICS · doi:10.1002/pmic.201300339 · Cited by 24
Simone, P., Pierri, G., Foglia, P., Gasparrini, F., Mazzoccanti, G., Capriotti, A. L., Ursini, O., Ciogli, A., & Laganà, A. (2016) · Journal of Separation Science · doi:10.1002/jssc.201500844 · Cited by 24
Metadata
- Authors
- Kelleher, N. L., Lin, H. Y., Valaskovic, G. A., Aaserud, D. J., Fridriksson, E. K., & McLafferty, F. W.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-01-16
- Volume
- 121
- Issue
- 4
- Pages
- 806-812
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1977291445
- Cited by
- 605
- References
- 24
- FWCI
- 11.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.