The DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Selective Visualization of the Endogenous Peroxynitrite in an Inflamed Mouse Model by a Mitochondria-Targetable Two-Photon Ratiometric Fluorescent Probe
Abstract
Peroxynitrite (ONOO – ) is a kind of reactive oxygen species (ROS) with super activity of oxidization and nitration, and overproduction of ONOO – is associated with pathogenesis of many diseases. Thus, accurate detection of ONOO – with high sensitivity and selectivity is imperative for elucidating its functions in health or disease states. Herein we for the first time present a new two-photon ratiometric fluorescent ONOO – probe ( MITO - CC ) based on FRET mechanism by combining rational design strategy and dye-screening approach. MITO - CC, with fast response rate (within 20 s), excellent sensitivity (detection limit = 11.30 nM) and outstanding selectivity toward ONOO –, was successfully applied to ratiometric detection of endogenous ONOO – produced by HepG2/RAW264.7 cells and further employed for imaging oxidative stress in an inflamed mouse model. Therefore, probe MITO - CC could be a potential biological tool to explore the roles of ONOO – under different physiological and pathological settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nitric Oxide and Peroxynitrite in Health and Disease
Pacher, P., Beckman, J. S., & Liaudet, L. (2007) · Physiological Reviews · doi:10.1152/physrev.00029.2006 · Cited by 6,390
Peroxynitrite oxidation of sulfhydryls.
Radi, R., Beckman, J. S., Bush, K. M., & Freeman, B. A. (1991) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(20)64313-7 · Cited by 2,490
Luminescent Chemodosimeters for Bioimaging
Yang, Y., Zhao, Q., Feng, W., & Li, F. (2013) · Chemical Reviews · doi:10.1021/cr2004103 · Cited by 2,236
Peroxynitrite: biochemistry, pathophysiology and development of therapeutics
Szabó, C., Ischiropoulos, H., & Radi, R. (2007) · Nature Reviews Drug Discovery · doi:10.1038/nrd2222 · Cited by 2,134
Antimicrobial reactive oxygen and nitrogen species: concepts and controversies
Fang, F. C. (2004) · Nature Reviews Microbiology · doi:10.1038/nrmicro1004 · Cited by 1,676
Zhou, M., Diwu, Z., Panchuk-Voloshina, N., & Haugland, R. P. (1997) · Analytical Biochemistry · doi:10.1006/abio.1997.2391 · Cited by 1,396
Setsukinai, K.-I., Urano, Y., Kakinuma, K., Majima, H. J., & Nagano, T. (2003) · Journal of Biological Chemistry · doi:10.1074/jbc.m209264200 · Cited by 1,301
Fluorescent Probes for Sensing and Imaging within Specific Cellular Organelles
Zhu, H., Fan, J., Du, J., & Peng, X. (2016) · Accounts of Chemical Research · doi:10.1021/acs.accounts.6b00292 · Cited by 984
Peroxynitrite, a Stealthy Biological Oxidant
Radi, R. (2013) · Journal of Biological Chemistry · doi:10.1074/jbc.r113.472936 · Cited by 888
Wardman, P. (2007) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2007.06.026 · Cited by 864
Cited by
Förster resonance energy transfer (FRET)-based small-molecule sensors and imaging agents
Wu, L., Huang, C., Emery, B. P., Sedgwick, A. C., Bull, S. D., He, X.-P., Tian, H., Yoon, J., Sessler, J. L., & James, T. D. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00318e · Cited by 1,026
Fluorescent probes for organelle-targeted bioactive species imaging
Gao, P., Pan, W., Li, N., & Tang, B. (2019) · Chemical Science · doi:10.1039/c9sc01652j · Cited by 599
Fluorescent Probes for Disease Diagnosis
Wang, X., Ding, Q., Groleau, R. R., Wu, L., Mao, Y., Che, F., Kotova, O., Scanlan, E. M., Lewis, S. E., Li, P., et al. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00776 · Cited by 543
Fluorescent small organic probes for biosensing
Tian, X., Murfin, L. C., Wu, L., Lewis, S. E., & James, T. D. (2021) · Chemical Science · doi:10.1039/d0sc06928k · Cited by 520
Jiao, X., Li, Y., Niu, J., Xie, X., Wang, X., & Tang, B. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04234 · Cited by 484
Lei, Z., Sun, C., Pei, P., Wang, S., Li, D., Zhang, X., & Zhang, F. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201904182 · Cited by 362
Self-citationRecent progress in the development of fluorescent probes for imaging pathological oxidative stress
Geng, Y., Wang, Z., Zhou, J., Zhu, M., Liu, J., & James, T. D. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00172a · Cited by 351
Hybrid Rhodamine Fluorophores in the Visible/NIR Region for Biological Imaging
Wang, L., Du, W., Hu, Z., Uvdal, K., Li, L., & Huang, W. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201901061 · Cited by 348
Self-citationWu, L., Liu, J., Li, P., Tang, B., & James, T. D. (2021) · Chemical Society Reviews · doi:10.1039/d0cs00861c · Cited by 348
Cheng, D., Peng, J., Lv, Y., Su, D., Liu, D., Chen, M., Yuan, L., & Zhang, X. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b01374 · Cited by 308
Self-citationSynthesis of Self-Assembled Porphyrin Nanoparticle Photosensitizers
Wang, D., Niu, L., Qiao, Z.-Y., Cheng, D.-B., Wang, J., Zhong, Y., Bai, F., Wang, H., & Fan, H. (2018) · ACS Nano · doi:10.1021/acsnano.8b01010 · Cited by 303
Self-citationFluorescent probes for the detection of disease-associated biomarkers
Dou, W.-T., Han, H.-H., Sedgwick, A. C., Zhu, G.-B., Zang, Y., Yang, X.-R., Yoon, J., James, T. D., Li, J., & He, X.-P. (2022) · Science Bulletin · doi:10.1016/j.scib.2022.01.014 · Cited by 266
Metadata
- Authors
- Cheng, D., Pan, Y., Wang, L., Zeng, Z., Yuan, L., Zhang, X., & Chang, Y.-T.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-12-20
- Volume
- 139
- Issue
- 1
- Pages
- 285-292
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2560717561
- Cited by
- 500
- References
- 65
- FWCI
- 29.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.