De Novo Design of Chemical Stability Near-Infrared Molecular Probes for High-Fidelity Hepatotoxicity Evaluation In Vivo

Cheng, Dan, Peng, Juanjuan, Lv, Yun, Su, Dongdong, Liu, Dongjie, Chen, Mei, Yuan, Lin, Zhang, Xiaobing·2019·Journal of the American Chemical Society

Abstract

Near-infrared (NIR) fluorescence imaging technique is garnering increasing research attention due to various advantages. However, most NIR fluorescent probes still suffer from a false signals problem owing to their instability in real application. Especially in a pathological environment, many NIR probes can be easily destroyed due to the excessive generation of highly reactive species and causing a distorted false signal. Herein, we proposed an approach for developing a new stable NIR dye platform with an optically tunable group to eliminate false signals using the combination of dyes screening and rational design strategy. The conception is validated by the construction of two high-fidelity NIR fluorescent probes ( NIR-LAP and NIR-ONOO – ) sensing leucine aminopeptidase (LAP) and peroxynitrite (ONOO – ), the markers of hepatotoxicity. These probes ( NIR-LAP and NIR-ONOO – ) were demonstrated to sensitively and accurately monitor LAP and ONOO – (detection limit: 80 mU/L for LAP and 90 nM for ONOO – ), thereby allowing one to precisely evaluate drug-induced hepatotoxicity. In addition, based on the fluctuation of LAP, the therapeutic efficacy of six hepatoprotective medicines for acetaminophen-induced hepatotoxicity was analyzed in vivo. We anticipate the high-fidelity NIR dye platform with an optically tunable group could provide a convenient and efficient tool for the development of future probes applied in the pathological environment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/jacs.9b01374

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 308

Metadata

Authors
Cheng, D., Peng, J., Lv, Y., Su, D., Liu, D., Chen, M., Yuan, L., & Zhang, X.
Venue
Journal of the American Chemical Society
Published
2019-03-22
Volume
141
Issue
15
Pages
6352-6361
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W2925268815
Cited by
308
References
3
FWCI
15.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: De Novo Design of Chemical Stability Near-Infrared Molecular Probes for High-Fidelity Hepatotoxicity Evaluation In Vivo. https://app.cochat.ai/papers/10.1021/jacs.9b01374
The paper
Cheng, D., Peng, J., Lv, Y., Su, D., Liu, D., Chen, M., Yuan, L., & Zhang, X. (2019). De Novo Design of Chemical Stability Near-Infrared Molecular Probes for High-Fidelity Hepatotoxicity Evaluation In Vivo. Journal of the American Chemical Society. https://doi.org/10.1021/jacs.9b01374

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.