The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
De Novo Design of Chemical Stability Near-Infrared Molecular Probes for High-Fidelity Hepatotoxicity Evaluation In Vivo
Abstract
Near-infrared (NIR) fluorescence imaging technique is garnering increasing research attention due to various advantages. However, most NIR fluorescent probes still suffer from a false signals problem owing to their instability in real application. Especially in a pathological environment, many NIR probes can be easily destroyed due to the excessive generation of highly reactive species and causing a distorted false signal. Herein, we proposed an approach for developing a new stable NIR dye platform with an optically tunable group to eliminate false signals using the combination of dyes screening and rational design strategy. The conception is validated by the construction of two high-fidelity NIR fluorescent probes ( NIR-LAP and NIR-ONOO – ) sensing leucine aminopeptidase (LAP) and peroxynitrite (ONOO – ), the markers of hepatotoxicity. These probes ( NIR-LAP and NIR-ONOO – ) were demonstrated to sensitively and accurately monitor LAP and ONOO – (detection limit: 80 mU/L for LAP and 90 nM for ONOO – ), thereby allowing one to precisely evaluate drug-induced hepatotoxicity. In addition, based on the fluctuation of LAP, the therapeutic efficacy of six hepatoprotective medicines for acetaminophen-induced hepatotoxicity was analyzed in vivo. We anticipate the high-fidelity NIR dye platform with an optically tunable group could provide a convenient and efficient tool for the development of future probes applied in the pathological environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Peroxynitrite: biochemistry, pathophysiology and development of therapeutics
Szabó, C., Ischiropoulos, H., & Radi, R. (2007) · Nature Reviews Drug Discovery · doi:10.1038/nrd2222 · Cited by 2,134
Recent progresses in small-molecule enzymatic fluorescent probes for cancer imaging
Liu, H.-W., Chen, L., Xu, C., Li, Z., Zhang, H., Zhang, X.-B., & Tan, W. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00862g · Cited by 948
Self-citationKnight, T. R. (2001) · Toxicological Sciences · doi:10.1093/toxsci/62.2.212 · Cited by 313
Cited by
J -Aggregates of Cyanine Dye for NIR-II in Vivo Dynamic Vascular Imaging beyond 1500 nm
Sun, C., Li, B., Zhao, M., Wang, S., Lei, Z., Lu, L., Zhang, H., Feng, L., Dou, C., Yin, D., et al. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b10043 · Cited by 582
Zeng, S., Liu, X., Kafuti, Y. S., Kim, H., Wang, J., Peng, X., Li, H., & Yoon, J. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00799a · Cited by 341
Ren, T., Wang, Z., Xiang, Z., Lu, P., Lai, H., Yuan, L., Zhang, X., & Tan, W. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202009986 · Cited by 273
Self-citationQin, Z., Ren, T., Zhou, H., Zhang, X., He, L., Li, Z., Zhang, X., & Yuan, L. (2022) · Angewandte Chemie International Edition · doi:10.1002/anie.202201541 · Cited by 140
Self-citation
Metadata
- Authors
- Cheng, D., Peng, J., Lv, Y., Su, D., Liu, D., Chen, M., Yuan, L., & Zhang, X.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-03-22
- Volume
- 141
- Issue
- 15
- Pages
- 6352-6361
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2925268815
- Cited by
- 308
- References
- 3
- FWCI
- 15.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: De Novo Design of Chemical Stability Near-Infrared Molecular Probes for High-Fidelity Hepatotoxicity Evaluation In Vivo. https://app.cochat.ai/papers/10.1021/jacs.9b01374
- The paper
- Cheng, D., Peng, J., Lv, Y., Su, D., Liu, D., Chen, M., Yuan, L., & Zhang, X. (2019). De Novo Design of Chemical Stability Near-Infrared Molecular Probes for High-Fidelity Hepatotoxicity Evaluation In Vivo. Journal of the American Chemical Society. https://doi.org/10.1021/jacs.9b01374
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.