Cell-Permeant Large Stokes Shift Dyes for Transfection-Free Multicolor Nanoscopy
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We designed cell-permeant red-emitting fluorescent dye labels with >140 nm Stokes shifts based on 9-iminoanthrone, 9-imino-10-silaxanthone, and 9-imino-10-germaxanthone fluorophores. The corresponding probes selectively targeting mitochondria, lysosomes, and F-actin demonstrate low toxicity and enable stimulated emission depletion (STED) nanoscopy in neurons, human fibroblasts, U2OS, and HeLa cells. In combination with known small Stokes shift dyes, our probes allow live-cell three-color STED nanoscopy of endogenous targets on popular setups with 775 nm STED wavelength.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Applying systems-level spectral imaging and analysis to reveal the organelle interactome
Valm, A. M., Cohen, S., Legant, W. R., Melunis, J., Hershberg, U., Wait, E., Cohen, A. R., Davidson, M. W., Betzig, E., & Lippincott-Schwartz, J. (2017) · Nature · doi:10.1038/nature22369 · Cited by 1,113
Lee, S., Sato, Y., & Nixon, R. A. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.6412-10.2011 · Cited by 470
Neurofascin assembles a specialized extracellular matrix at the axon initial segment
Hedstrom, K. L., Xu, X., Ogawa, Y., Frischknecht, R., Seidenbecher, C. I., Shrager, P., & Rasband, M. N. (2007) · The Journal of Cell Biology · doi:10.1083/jcb.200705119 · Cited by 268
Cited by
Small-Molecule Fluorescent Probes for Live-Cell Super-Resolution Microscopy
Wang, L., Frei, M. S., Salim, A., & Johnsson, K. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.8b11134 · Cited by 504
A General Method To Increase Stokes Shift by Introducing Alternating Vibronic Structures
Ren, T.-B., Xu, W., Zhang, W., Zhang, X.-X., Wang, Z.-Y., Xiang, Z., Yuan, L., & Zhang, X.-B. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.8b04404 · Cited by 443
Hybrid Rhodamine Fluorophores in the Visible/NIR Region for Biological Imaging
Wang, L., Du, W., Hu, Z., Uvdal, K., Li, L., & Huang, W. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201901061 · Cited by 348
Emerging applications of carbon nanohoops
Leonhardt, E. J., & Jasti, R. (2019) · Nature Reviews Chemistry · doi:10.1038/s41570-019-0140-0 · Cited by 340
Constitutional Isomerization Enables Bright NIR‐II AIEgen for Brain‐Inflammation Imaging
Liu, S., Chen, C., Li, Y., Zhang, H., Liu, J., Wang, R., Wong, S. T. H., Lam, J. W. Y., Ding, D., & Tang, B. Z. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201908125 · Cited by 267
Metadata
- Authors
- Butkevich, A. N., Lukinavičius, G., D’Este, E., & Hell, S. W.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-08-30
- Volume
- 139
- Issue
- 36
- Pages
- 12378-12381
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2745320090
- Cited by
- 151
- References
- 3
- FWCI
- 8.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cell-Permeant Large Stokes Shift Dyes for Transfection-Free Multicolor Nanoscopy. https://app.cochat.ai/papers/10.1021/jacs.7b06412
- The paper
- Butkevich, A. N., Lukinavičius, G., D’Este, E., & Hell, S. W. (2017). Cell-Permeant Large Stokes Shift Dyes for Transfection-Free Multicolor Nanoscopy. Journal of the American Chemical Society. https://doi.org/10.1021/jacs.7b06412
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.