The DOI matches its Crossref record.
High-Throughput Assay of Oxygen Radical Absorbance Capacity (ORAC) Using a Multichannel Liquid Handling System Coupled with a Microplate Fluorescence Reader in 96-Well Format
Abstract
The oxygen radical absorbance capacity (ORAC) assay has been widely accepted as a standard tool to measure the antioxidant activity in the nutraceutical, pharmaceutical, and food industries. However, the ORAC assay has been criticized for a lack of accessibility due to the unavailability of the COBAS FARA II analyzer, an instrument discontinued by the manufacturer. In addition, the manual sample preparation is time-consuming and labor-intensive. The objective of this study was to develop a high-throughput instrument platform that can fully automate the ORAC assay procedure. The new instrument platform consists of a robotic eight-channel liquid handling system and a microplate fluorescence reader. By using the high-throughput platform, the efficiency of the assay is improved with at least a 10-fold increase in sample throughput over the current procedure. The mean of intra- and interday CVs was
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Chemistry behind Antioxidant Capacity Assays
Huang, D., Ou, B., & Prior, R. L. (2005) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf030723c · Cited by 6,162
Self-citationAntioxidants and antioxidant methods: an updated overview
Gulcin, İ. (2020) · Archives of Toxicology · doi:10.1007/s00204-020-02689-3 · Cited by 2,205
Fluorescence probes used for detection of reactive oxygen species
Gomes, A., Fernandes, E., & Lima, J. L. F. C. (2005) · Journal of Biochemical and Biophysical Methods · doi:10.1016/j.jbbm.2005.10.003 · Cited by 1,844
Prior, R. L., Hoang, H., Gu, L., Wu, X., Bacchiocca, M., Howard, L., Hampsch-Woodill, M., Huang, D., Ou, B., & Jacob, R. (2003) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf0262256 · Cited by 1,455
Self-citationExtending Applicability of the Oxygen Radical Absorbance Capacity (ORAC−Fluorescein) Assay
Dávalos, A., Gómez-Cordovés, C., & Bartolomé, B. (2004) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf0305231 · Cited by 1,207
Metadata
- Authors
- Huang, D., Ou, B., Hampsch-Woodill, M., Flanagan, J. A., & Prior, R. L.
- Venue
- Journal of Agricultural and Food Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-07-01
- Volume
- 50
- Issue
- 16
- Pages
- 4437-4444
- ISSN
- 0021-8561 (ISSN-L)
- 1520-5118
- OpenAlex
- W2090678272
- Cited by
- 1,566
- References
- 0
- FWCI
- 5.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Throughput Assay of Oxygen Radical Absorbance Capacity (ORAC) Using a Multichannel Liquid Handling System Coupled with a Microplate Fluorescence Reader in 96-Well Format. https://app.cochat.ai/papers/10.1021/jf0201529
- The paper
- Huang, D., Ou, B., Hampsch-Woodill, M., Flanagan, J. A., & Prior, R. L. (2002). High-Throughput Assay of Oxygen Radical Absorbance Capacity (ORAC) Using a Multichannel Liquid Handling System Coupled with a Microplate Fluorescence Reader in 96-Well Format. Journal of Agricultural and Food Chemistry. https://doi.org/10.1021/jf0201529
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.