Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 232

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Phenolic Compounds and Antioxidant Activity of Extracts from Ultrasonic Treatment of Satsuma Mandarin (Citrus unshiu Marc.) Peels

Ma, Ya-Qin, Ye, Xing-Qian, Fang, Zhong-Xiang, Chen, Jian-Chu, Xu, Gui-Hua, Liu, Dong-Hong · 2008 · Journal of Agricultural and Food Chemistry

Abstract

Ultrasound-assisted extraction (UAE) was used to extract phenolic compounds from Satsuma mandarin ( Citrus unshiu Marc.) peels (SMP), and maceration extraction (ME) was used as a control. The effects of ultrasonic time (10, 20, 30, 40, 50, and 60 min), temperature (15, 30, and 40 degrees C), and ultrasonic power (3.2, 8, 30, and 56 W) on phenolic compounds were investigated. High-performance liquid chromatography (HPLC) coupled with a photodiode array (PDA) detector was used for the analysis of phenolic acids after alkaline hydrolysis (bound phenolic acids) and flavanone glycosides. The contents of seven phenolic acids (caffeic acid, p-coumaric acid, ferulic acid, sinapic acid, protocatechuic acid, p-hydroxybenzoic acid, and vanillic acid) and two flavanone glycosides (narirutin and hesperidin) in extracts obtained by ultrasonic treatment were significantly higher than in extracts obtained by the maceration method. Moreover, the contents of extracts increased as both treatment time and temperature increased. Ultrasonic power had a positive effect on the contents of extracts. However, the phenolic acids may be degraded by ultrasound at higher temperature for a long time. For example, after ultrasonic treatment at 40 degrees C for 20 min, the contents of caffeic acid, p-coumaric acid, ferulic acid, and p-hydroxybenzoic acid decreased by 48.90, 44.20, 48.23, and 35.33%, respectively. The interaction of ultrasonic parameters probably has a complex effect on the extracts. A linear relationship was observed between Trolox equivalent antioxidant capacity (TEAC) values and total phenolic contents (TPC); the correlation coefficient, R(2), is 0.8288 at 15 degrees C, 0.7706 at 30 degrees C, and 0.8626 at 40 degrees C, respectively. The data indicated that SMPs were rich sources of antioxidants. Furthermore, UAE techniques should be carefully used to enhance the yields of phenolic acids from SMPs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/jf072474o

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 232

Metadata

Authors
Ma, Y.-Q., Ye, X.-Q., Fang, Z.-X., Chen, J.-C., Xu, G.-H., & Liu, D.-H.
Venue
Journal of Agricultural and Food Chemistry
Published
2008-06-24
Volume
56
Issue
14
Pages
5682-5690
ISSN
  • 0021-8561 (ISSN-L)
  • 1520-5118
OpenAlex
W1987195341
Cited by
232
References
2
FWCI
5.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.