Highly Efficient and Controllable PEGylation of Gold Nanoparticles Prepared by Femtosecond Laser Ablation in Water
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper demonstrates a new method for fabrication of stable gold nanoparticle–poly(ethylene glycol) (PEG) conjugates bearing a defined number of one or multiple types of PEG molecules. The PEG molecules are directly bound to the surface of gold nanoparticles with almost 100% conjugation efficiency, and the PEG surface coverage is tunable to be any percent value between 0 and 100%. The method comprises preparation of a colloidal suspension of naturally negative charged pure gold nanoparticles with a bare surface via a novel approach of femtosecond laser ablation of gold bulk target in deionized water first, and then the surface modification with PEG is carried out by adding PEG molecules containing thiol groups. It is revealed that because of their unique bare surface very efficient and controlled conjugation of PEG molecules to these gold nanoparticles could be achieved. The PEGylation process described in this paper just serves as one example to testify that the bare surface of gold nanoparticles provides significant benefits for their further surface modifications. The discussed strategies are of a general nature and could be readily applied in the same way to construct a mixed monolayer composed of other biologically important molecules onto the surface of a gold nanoparticle to form a multifunctional composite nanoparticle for offering improved performance in biomedical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
Cited by
Laser Synthesis and Processing of Colloids: Fundamentals and Applications
Zhang, D., Gökce, B., & Barcikowski, S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00468 · Cited by 1,344
Smart nanocarrier-based drug delivery systems for cancer therapy and toxicity studies: A review
Hossen, S., Hossain, M. K., Basher, M. K., Mia, M. N. H., Rahman, M. T., & Uddin, M. J. (2019) · Journal of Advanced Research · doi:10.1016/j.jare.2018.06.005 · Cited by 998
“Under physiological conditions, PEGylated GNPs show enhanced solubility and stability [122].”
BackgroundNanoadsorbents: Classification, Preparation, and Applications (with Emphasis on Aqueous Media)
Khajeh, M., Laurent, S., & Dastafkan, K. (2013) · Chemical Reviews · doi:10.1021/cr400086v · Cited by 528
Advanced nanoparticle generation and excitation by lasers in liquids
Barcikowski, S., & Compagnini, G. (2013) · Phys. Chem. Chem. Phys. · doi:10.1039/c2cp90132c · Cited by 287
Nanomaterials for Photo-Based Diagnostic and Therapeutic Applications
Menon, J. U., Jadeja, P., Tambe, P., Vu, K., Yuan, B., & Nguyen, K. T. (2013) · Theranostics · doi:10.7150/thno.5327 · Cited by 284
Metadata
- Authors
- Qian, W., Murakami, M., Ichikawa, Y., & Che, Y.
- Venue
- The Journal of Physical Chemistry C
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-11-04
- Volume
- 115
- Issue
- 47
- Pages
- 23293-23298
- ISSN
- 1932-7447 (ISSN-L)
- 1932-7455
- OpenAlex
- W2314217080
- Cited by
- 92
- References
- 1
- FWCI
- 2.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.