Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 240

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

CoP as an Acid-Stable Active Electrocatalyst for the Hydrogen-Evolution Reaction: Electrochemical Synthesis, Interfacial Characterization and Performance Evaluation

Open access
Saadi, Fadl H., Carim, Azhar I., Verlage, Erik, Hemminger, John C., Lewis, Nathan S., Soriaga, Manuel P.·2014·The Journal of Physical Chemistry C

Abstract

Films of CoP have been electrochemically synthesized, characterized, and evaluated for performance as a catalyst for the hydrogen-evolution reaction (HER). The film was synthesized by cathodic deposition from a boric acid solution of Co 2+ and H 2 PO 2 – on copper substrates followed by operando remediation of exogenous contaminants. The films were characterized structurally and compositionally by scanning-electron microscopy, energy-dispersive X-ray spectroscopy, X-ray photoelectron spectroscopy, and Raman spectrophotometry. The catalytic activity was evaluated by cyclic voltammetry and chronopotentiometry. Surface characterization prior to electrocatalysis indicated that the film consisted of micrometer-sized spherical clusters located randomly and loosely on a slightly roughened surface. The composition of both the clusters and surface consisted of cobalt in the metallic, phosphide, and amorphous-oxide forms (CoO·Co 2 O 3 ) and of phosphorus as phosphide and orthophosphate. The orthophosphate species, produced by air-oxidation, were eliminated upon HER electrocatalysis in sulfuric acid. The operando film purification yielded a functional electrocatalyst with a Co:P stoichiometric ratio of 1:1. After the HER, the surface was densely packed with micrometer-sized, mesa-like particles whose tops were flat and smooth. The CoP eletrodeposit exhibited an 85 mV overvoltage (η) for the HER at a current density of 10 mA cm –2 and was stable under operation in highly acidic solution, with an increase in η of 18 mV after 24 h of continuous operation. The comparative HER catalytic performance of CoP, film or nanoparticles, is as follows: η Pt < η CoP film = η CoP NP, η Ni 2 P < η CoSe 2 < η MoS 2 < η MoSe 2 .

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/jp5054452

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 240

Metadata

Authors
Saadi, F. H., Carim, A. I., Verlage, E., Hemminger, J. C., Lewis, N. S., & Soriaga, M. P.
Venue
The Journal of Physical Chemistry C
Published
2014-10-10
Volume
118
Issue
50
Pages
29294-29300
ISSN
  • 1932-7447 (ISSN-L)
  • 1932-7455
OpenAlex
W2054211043
Cited by
240
References
9
FWCI
9.39
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.