The DOI matches its Crossref record.
Optimal Design and Characterization of Superparamagnetic Iron Oxide Nanoparticles Coated with Polyvinyl Alcohol for Targeted Delivery and Imaging
Abstract
Superparamagnetic iron oxide nanoparticles (SPION) with narrow size distribution and stabilized by polyvinyl alcohol (PVA) were synthesized. The particles were prepared by a coprecipitation technique using ferric and ferrous salts with a molar Fe3+/Fe2+ ratio of 2. Using a design of experiments (DOE) approach, the effect of different synthesis parameters (stirring rate and base molarity) on the structure, morphology, saturation magnetization, purity, size, and size distribution of the synthesized magnetite nanoparticles was studied by various analysis techniques including X-ray powder diffraction (XRD), thermogravimetric analysis (TGA) with differential scanning calorimetry (DSC) measurements, vibrating-sample magnetometer (VSM), transmission electron microscopy (TEM), UV-visible, and Fourier transform infrared (FT-IR) spectrometer. PVA not only stabilized the colloid but also played a role in preventing further growth of SPION followed by the formation of large agglomerates by chemisorption on the surface of particles. A rich behavior in particle size, particle formation, and super paramagnetic properties is observed as a function of molarity and stirring conditions. The particle size and the magnetic properties as well as particle shape and aggregation (individual nanoparticles, magnetic beads, and magnetite colloidal nanocrystal clusters (CNCs) are found to be influenced by changes in the stirring rate and the base molarity. The formation of magnetic beads results in a decrease in the saturation magnetization, while CNCs lead to an increase in saturation magnetization. On the basis of the DOE methodology and the resulting 3-D response surfaces for particle size and magnetic properties, it is shown that optimum regions for stirring rate and molarity can be obtained to achieve coated SPION with desirable size, purity, magnetization, and shape.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sharifi, S., Behzadi, S., Laurent, S., Laird Forrest, M., Stroeve, P., & Mahmoudi, M. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15188f · Cited by 1,460
Self-citationMagnetic fluid hyperthermia: focus on superparamagnetic iron oxide nanoparticles
Laurent, S., Dutz, S., Häfeli, U. O., & Mahmoudi, M. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2011.04.003 · Cited by 1,326
Self-citationMetal/Semiconductor Hybrid Nanostructures for Plasmon‐Enhanced Applications
Jiang, R., Li, B., Fang, C., & Wang, J. (2014) · Advanced Materials · doi:10.1002/adma.201400203 · Cited by 1,156
Mahmoudi, M., Simchi, A., Imani, M., Shokrgozar, M. A., Milani, A. S., Häfeli, U. O., & Stroeve, P. (2010) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2009.08.044 · Cited by 294
Application of Iron Magnetic Nanoparticles in Protein Immobilization
Xu, J., Sun, J., Wang, Y., Sheng, J., Wang, F., & Sun, M. (2014) · Molecules · doi:10.3390/molecules190811465 · Cited by 290
Metadata
- Authors
- Mahmoudi, M., Simchi, A., Imani, M., Milani, A. S., & Stroeve, P.
- Venue
- The Journal of Physical Chemistry B
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-08-26
- Volume
- 112
- Issue
- 46
- Pages
- 14470-14481
- ISSN
- 1520-5207 (ISSN-L)
- 1520-6106
- OpenAlex
- W2051183893
- Cited by
- 253
- References
- 0
- FWCI
- 11.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal Design and Characterization of Superparamagnetic Iron Oxide Nanoparticles Coated with Polyvinyl Alcohol for Targeted Delivery and Imaging. https://app.cochat.ai/papers/10.1021/jp803016n
- The paper
- Mahmoudi, M., Simchi, A., Imani, M., Milani, A. S., & Stroeve, P. (2008). Optimal Design and Characterization of Superparamagnetic Iron Oxide Nanoparticles Coated with Polyvinyl Alcohol for Targeted Delivery and Imaging. The Journal of Physical Chemistry B. https://doi.org/10.1021/jp803016n
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.