Injectable Biodegradable Thermosensitive Hydrogel Composite for Orthopedic Tissue Engineering. 1. Preparation and Characterization of Nanohydroxyapatite/Poly(ethylene glycol)−Poly(ε-caprolactone)−Poly(ethylene glycol) Hydrogel Nanocomposites
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
In this study, we synthesized a biodegradable triblock copolymer poly(ethylene glycol)-poly(epsilon-caprolactone)-poly(ethylene glycol) (PEG-PCL-PEG, PECE) by ring-opening copolymerization, and nanohydroxyapatite (n-HA) powder was prepared by a hydrothermal precipitation method. The obtained n-HA was incorporated into the PECE matrix to prepare injectable thermosensitive hydrogel nanocomposites. (1)H NMR, FT-IR, XRD, DSC, and TEM were used to investigate the properties of PECE copolymer and n-HA/PECE nanocomposites. The rheological measurements for n-HA/PECE nanocomposites revealed that the gelation temperature was approximately 36 degrees C. The sol-gel-sol transition behavior and phase transition diagrams were recorded through a test tube inverting method. The results showed that n-HA/PECE nanocomposites still had thermoresponsivity like that of PECE thermosensitive hydrogel. The morphology of the nanocomposites was observed by SEM; the results showed that the nanocomposites had a 3D network structure. In addition, the effects of n-HA contents on the properties of n-HA/PECE nanocomposites are also discussed in the paper. From the results, n-HA/PECE hydrogel is believed to be promising for injectable orthopedic tissue engineering due to its good thermosensitivity and injectability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermosensitive sol-gel reversible hydrogels
Jeong, B., Kim, S. W., & Bae, Y. H. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00242-3 · Cited by 1,478
Chitosan and its derivatives for tissue engineering applications
Kim, I.-Y., Seo, S.-J., Moon, H.-S., Yoo, M.-K., Park, I.-Y., Kim, B.-C., & Cho, C.-S. (2008) · Biotechnology Advances · doi:10.1016/j.biotechadv.2007.07.009 · Cited by 1,433
Injectable biodegradable materials for orthopedic tissue engineering
Temenoff, J. S., & Mikos, A. G. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00108-3 · Cited by 554
Gong, C., Qian, Z., Liu, C., Huang, M., Gu, Y., Wen, Y., Kan, B., Wang, K., Dai, M., Li, X., et al. (2007) · Smart Materials and Structures · doi:10.1088/0964-1726/16/3/043 · Cited by 73
Self-citation
Cited by
Injectable and biodegradable hydrogels: gelation, biodegradation and biomedical applications
Li, Y., Rodrigues, J., & Tomás, H. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15203c · Cited by 1,445
Polyethylene glycol (PEG): A versatile polymer for pharmaceutical applications
D’souza, A. A., & Shegokar, R. (2016) · Expert Opinion on Drug Delivery · doi:10.1080/17425247.2016.1182485 · Cited by 1,282
“[133] Scientists are looking for various ways to improve mechanical properties of PEG gels in vivo .”
Injectable hydrogels for cartilage and bone tissue engineering
Liu, M., Zeng, X., Ma, C., Yi, H., Ali, Z., Mou, X., Li, S., Deng, Y., & He, N. (2017) · Bone Research · doi:10.1038/boneres.2017.14 · Cited by 1,211
Temperature-responsive compounds as in situ gelling biomedical materials
Moon, H. J., Ko, D. Y., Park, M. H., Joo, M. K., & Jeong, B. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35078e · Cited by 421
Zhao, F., Yao, D., Guo, R., Deng, L., Dong, A., & Zhang, J. (2015) · Nanomaterials · doi:10.3390/nano5042054 · Cited by 400
Metadata
- Authors
- Fu, S., Guo, G., Gong, C., Zeng, S., Liang, H., Luo, F., Zhang, X., Zhao, X., Wei, Y., & Qian, Z.
- Venue
- The Journal of Physical Chemistry B
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-11-30
- Volume
- 113
- Issue
- 52
- Pages
- 16518-16525
- ISSN
- 1520-5207 (ISSN-L)
- 1520-6106
- OpenAlex
- W2009392548
- Cited by
- 90
- References
- 4
- FWCI
- 2.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.