Properties of Aqueous Solutions and Gels of Poly(ethylene oxide)-b-poly(propylene oxide)-b-poly(ethylene oxide)-g-poly(acrylic acid)
The DOI matches its Crossref record.
Abstract
Gelation in aqueous solutions of poly(acrylic acid) (PAA) grafted onto poly(ethylene oxide)- b -poly(propylene oxide)- b -poly(ethylene oxide) (Pluronic F127) has been studied. The gel point and onset of micellization are observed in Pluronic−PAA solutions at the same temperatures, confirming that the gelation occurs via formation of micelles that act as thermoreversible cross-links. The salt- and pH-dependent expansion or folding of the polyelectrolyte segments changes the gel elasticity. The increased polarity due to enhanced polymer ionization at higher pH or with salt addition causes the poly(propylene oxide) (PPO) segments to aggregate at lower temperatures. The weak dependence of the polymer concentration at the maximum reduced viscosity on the salt concentration is attributed to hydrophobic interactions among PPO segments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Stimuli-reponsive polymers and their bioconjugates
GIL, E., & HUDSON, S. (2004) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2004.08.003 · Cited by 2,385
Thermosensitive sol-gel reversible hydrogels
Jeong, B., Kim, S. W., & Bae, Y. H. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00242-3 · Cited by 1,478
In situ-forming hydrogels--review of temperature-sensitive systems
Ruel-Gariépy, E., & Leroux, J.-C. (2004) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2004.03.019 · Cited by 1,297
“Besides polymer concentration, pH and salts influenced gelation properties [102].”
BackgroundLessons from nature: stimuli-responsive polymers and their biomedical applications
Jeong, B., & Gutowska, A. (2002) · Trends in Biotechnology · doi:10.1016/s0167-7799(02)01962-5 · Cited by 856
Thermosensitive sol–gel reversible hydrogels
Jeong, B., Kim, S. W., & Bae, Y. H. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.09.012 · Cited by 533
Sosnik, A., das Neves, J., & Sarmento, B. (2014) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2014.07.010 · Cited by 487
Roy, I., & Gupta, M. N. (2003) · Chemistry & Biology · doi:10.1016/j.chembiol.2003.12.004 · Cited by 371
New polymeric architectures with (meth)acrylic acid segments
Mori, H., & Müller, A. H. E. (2003) · Progress in Polymer Science · doi:10.1016/s0079-6700(03)00076-5 · Cited by 277
Polymeric micelles in oral chemotherapy
Bromberg, L. (2008) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.01.018 · Cited by 264
Self-citationPolyelectrolyte Block Copolymer Micelles
Förster, S., Abetz, V., & Müller, A. H. E. (2012) · Advances in Polymer Science · doi:10.1007/b11351 · Cited by 190
Polymeric micelles in mucosal drug delivery: challenges towards clinical translation
Sosnik, A., & Menaker Raskin, M. (2015) · Biotechnology Advances · doi:10.1016/j.biotechadv.2015.01.003 · Cited by 154
Metadata
- Authors
- Bromberg, L.
- Venue
- The Journal of Physical Chemistry B
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-12-01
- Volume
- 102
- Issue
- 52
- Pages
- 10736-10744
- ISSN
- 1520-5207 (ISSN-L)
- 1520-6106
- OpenAlex
- W2086489212
- Cited by
- 81
- References
- 0
- FWCI
- 1.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.