Characterization of Glucose-Mediated Insulin Release from Implantable Polymers
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We characterized a glucose-sensitive, controlled-release insulin delivery system. Insulin release rates increased when glucose was perfused in the release media surrounding the matrix. The system was composed of solid, particulate insulin, incorporated into an ethylene-vinyl acetate copolymer (EVAc) matrix. Feedback control was mediated by the glucose oxidase enzyme immobilized to Sepharose beads, which were incorporated along with insulin into the EVAc matrix. When glucose in solution entered the insulin delivery system, gluconic acid was produced, causing a drop in the microenvironmental pH of the matrix. This fall in pH resulted in a rise in insulin solubility and consequently a rise in the insulin release rate from the matrix. Insulin concentrations increased in vitro and in vivo in response to glucose infusion. The increased insulin release was shown to consist of a finite pulse of insulin that required an optimal recovery period of 1 h to achieve a maximal repeated response to a glucose stimulus. Repeated pulses were demonstrated over a 4 h period. An optimum enzyme ratio was also determined.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Immunoassay of endogenous plasma insulin in man
Yalow, R. S., & Berson, S. A. (1960) · Journal of Clinical Investigation · doi:10.1172/jci104130 · Cited by 3,041
Microencapsulated Islets as Bioartificial Endocrine Pancreas
Lim, F., & Sun, A. M. (1980) · Science · doi:10.1126/science.6776628 · Cited by 2,377
Polymers for the sustained release of proteins and other macromolecules
LANGER, R., & FOLKMAN, J. (1976) · Nature · doi:10.1038/263797a0 · Cited by 1,182
Self-citation
Cited by
Hydrogels: From controlled release to pH-responsive drug delivery
Gupta, P., Vermani, K., & Garg, S. (2002) · Drug Discovery Today · doi:10.1016/s1359-6446(02)02255-9 · Cited by 1,825
Biomedical surface science: Foundations to frontiers
Castner, D. G., & Ratner, B. D. (2002) · Surface Science · doi:10.1016/s0039-6028(01)01587-4 · Cited by 1,329
Therapeutic applications of implantable drug delivery systems
Dash, A., & Cudworth, G. (1998) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/s1056-8719(98)00027-6 · Cited by 358
New frontiers in nanotechnology for cancer treatment
Alexis, F., Rhee, J.-W., Richie, J. P., Radovic-Moreno, A. F., Langer, R., & Farokhzad, O. C. (2008) · Urologic Oncology: Seminars and Original Investigations · doi:10.1016/j.urolonc.2007.03.017 · Cited by 347
Self-citationCharacterization of glucose-sensitive insulin release systems in simulated in vivo conditions
Traitel, T., Cohen, Y., & Kost, J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00050-8 · Cited by 253
Metadata
- Authors
- Brown, L. R., Edelman, E. R., Fischel-Ghodsian, F., & Langer, R.
- Venue
- Journal of Pharmaceutical Sciences
- Publisher
- American Geophysical Union (AGU)
- Published
- 1996-12
- Volume
- 85
- Issue
- 12
- Pages
- 1341-1345
- ISSN
- 0022-3549 (ISSN-L)
- OpenAlex
- W2092164369
- Cited by
- 55
- References
- 3
- FWCI
- 1.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterization of Glucose-Mediated Insulin Release from Implantable Polymers. https://app.cochat.ai/papers/10.1021/js9600686
- The paper
- Brown, L. R., Edelman, E. R., Fischel-Ghodsian, F., & Langer, R. (1996). Characterization of Glucose-Mediated Insulin Release from Implantable Polymers. Journal of Pharmaceutical Sciences. https://doi.org/10.1021/js9600686
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.