Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 221

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Incorporation and Release of Hydrophobic Probes in Biocompatible Polycaprolactone-block-poly(ethylene oxide) Micelles: Implications for Drug Delivery

Lim Soo, Patrick, Luo, Laibin, Maysinger, Dusica, Eisenberg, Adi·2002·Langmuir

Abstract

Block copolymer micelles have shown high potential as hydrophobic drug carriers. The loading efficiency, partition coefficient, and release profile all play critical roles in micellar drug delivery. As part of a series of studies on these polycaprolactone- block -poly(ethylene oxide) (PCL - b -PEO) micelles in drug delivery, we investigated the solubilization and release of the hydrophobic probes, benzo[ a ]pyrene and Cell-Tracker CM-DiI (DiI) from these micelles using fluorescence spectroscopy. The same method was also used to determine the partition coefficients of each probe between the core and the exterior solution, which were calculated at different solvent compositions and extrapolated to 100% water. The maximum loading efficiencies of DiI and benzo[ a ]pyrene were 87% and 32%, respectively. The large difference in the loading efficiency is related to the values of the partition coefficients, which were calculated to be 5800 for DiI and 700 for benzo[ a ]pyrene. DiI is more highly miscible with the polycaprolactone core compared to benzo[ a ]pyrene. The release of the hydrophobic probes from the micelles showed a biphasic profile under “perfect sink” conditions; there is an initial burst release, followed by a slow and prolonged release until, eventually, complete release is achieved. The release of the probes from the micelles is under diffusion control as shown by the linearity of the release as a function of the square root of time. Approximate diffusion constants of the order of 10 - 15 cm 2 /s for DiI and benzo[ a ]pyrene were obtained. We demonstrate that the type and the concentration of the incorporated agent influence the loading and the release from PCL- b -PEO micelles. In addition to providing new information on the incorporation and release of benzo[ a ]pyrene and DiI from these micelles, this study also demonstrates the importance of probe−micelle compatibility in the evaluation of a micellar drug delivery system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/la026339b

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Lim Soo, P., Luo, L., Maysinger, D., & Eisenberg, A.
Venue
Langmuir
Published
2002-11-07
Volume
18
Issue
25
Pages
9996-10004
ISSN
  • 0743-7463 (ISSN-L)
  • 1520-5827
OpenAlex
W2089066669
Cited by
221
References
4
FWCI
5.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.