Effect of an Oscillating Magnetic Field on the Release Properties of Magnetic Collagen Gels
Open accessThe DOI matches its Crossref record.
Abstract
The paper describes the effect of an oscillating magnetic field (OMF) on the morphology and release properties of collagen gels containing magnetic nanoparticles and microparticles and fluorescent drug analogues. Collagen gels were prepared through fibrillogenesis of collagen in the presence of iron oxide magnetic particles averaging 10 nm or 3 mum in diameter and rhodamine-labeled dextran (Dex-R) of molecular weights between 3000-70 000 g/mol. Dextran molecules effectively simulate protein-based drugs, since they have similar molecular weights and dimensions. The paper discusses the effect of an OMF on the release properties of the gels and proposes an empirical model to predict the release rate. It also demonstrates the self-repair capability of collagen gels following the structural damage caused by an OMF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Magnetic Hydrogels and Their Potential Biomedical Applications
Li, Y., Huang, G., Zhang, X., Li, B., Chen, Y., Lu, T., Lu, T. J., & Xu, F. (2013) · Advanced Functional Materials · doi:10.1002/adfm.201201708 · Cited by 721
Stimuli-responsive bio-based polymeric systems and their applications
Gao, S., Tang, G., Hua, D., Xiong, R., Han, J., Jiang, S., Zhang, Q., & Huang, C. (2019) · Journal of Materials Chemistry B · doi:10.1039/c8tb02491j · Cited by 605
Iron Oxide Nanoparticles for Magnetically-Guided and Magnetically-Responsive Drug Delivery
Estelrich, J., Escribano, E., Queralt, J., & Busquets, M. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms16048070 · Cited by 532
Magnetic hydrogel nanocomposites for remote controlled pulsatile drug release
SATARKAR, N., & HILT, J. (2008) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.06.008 · Cited by 505
Stimuli-responsive magnetic particles for biomedical applications
Medeiros, S. F., Santos, A. M., Fessi, H., & Elaissari, A. (2011) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.10.011 · Cited by 460
Oh, J. K., & Park, J. M. (2011) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.08.005 · Cited by 427
Hydrogel nanocomposites: a review of applications as remote controlled biomaterials
Satarkar, N. S., Biswal, D., & Hilt, J. Z. (2010) · Soft Matter · doi:10.1039/b925218p · Cited by 323
Zhang, J., Rana, S., Srivastava, R. S., & Misra, R. D. K. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.06.006 · Cited by 277
Biomedical nanoparticle carriers with combined thermal and magnetic responses
Liu, T.-Y., Hu, S.-H., Liu, D.-M., Chen, S.-Y., & Chen, I.-W. (2009) · Nano Today · doi:10.1016/j.nantod.2008.10.011 · Cited by 273
Magnetoliposomes for controlled drug release in the presence of low-frequency magnetic field
Nappini, S., Bombelli, F. B., Bonini, M., Nordèn, B., & Baglioni, P. (2010) · Soft Matter · doi:10.1039/b915651h · Cited by 113
Yang, L., Patel, K. D., Rathnam, C., Thangam, R., Hou, Y., Kang, H., & Lee, K. (2022) · Small · doi:10.1002/smll.202104783 · Cited by 81
Metadata
- Authors
- De Paoli, V. M., De Paoli Lacerda, S. H., Spinu, L., Ingber, B., Rosenzweig, Z., & Rosenzweig, N.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-05-13
- Volume
- 22
- Issue
- 13
- Pages
- 5894-5899
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2072697541
- Cited by
- 79
- References
- 0
- FWCI
- 1.88
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.