The DOI matches its Crossref record.
Shape-Controlled Production of Biodegradable Calcium Alginate Gel Microparticles Using a Novel Microfluidic Device
Abstract
In this paper we describe a novel method of manufacturing shape-controlled calcium alginate gel microparticles in a microfluidic device. Both manufacturing shape-controlled microparticles and synthesizing hydrogel microparticles could be performed simultaneously in the microfluidic device. The novel microfluidic device comprised of two individual flow-focusing channels and a synthesizing channel was successfully applied as a continuous microfluidic reactor to synthesize gel microparticles with size and shape control. By passive control based on the microchannel geometric confinement and liquid-phase flow rates, we succeeded in producing monodisperse sodium alginate microparticles with diverse shapes (such as plugs, disks, microspheres, rods, and threads) in the flow-focusing channels of the microfluidic device. The shape and size of the sodium alginate microparticles could be tuned by adjusting the flow rates of the various streams. Further stages of the chemical reaction could be initiated by mixing sodium alginate microparticles and calcium chloride (CaCl2) solution in the synthesizing channel. The shapes of the sodium alginate microparticles could be permanently preserved by the synthesis of calcium alginate gel microparticles. The preparation conditions of size- and shape-controlled calcium alginate microparticles and influence factors were studied.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Alginate: Properties and biomedical applications
Lee, K. Y., & Mooney, D. J. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.06.003 · Cited by 8,095
Teh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
The development of microgels/nanogels for drug delivery applications
Oh, J. K., Drumright, R., Siegwart, D. J., & Matyjaszewski, K. (2008) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.01.002 · Cited by 1,598
Microfluidic methods for generating continuous droplet streams
Christopher, G. F., & Anna, S. L. (2007) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/40/19/r01 · Cited by 860
Alginate gel particles–A review of production techniques and physical properties
Ching, S. H., Bansal, N., & Bhandari, B. (2017) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408398.2014.965773 · Cited by 651
Monodisperse Alginate Hydrogel Microbeads for Cell Encapsulation
Tan, W. ‐., & Takeuchi, S. (2007) · Advanced Materials · doi:10.1002/adma.200700433 · Cited by 599
Biopolymer-based microgels/nanogels for drug delivery applications
Oh, J. K., Lee, D. I., & Park, J. M. (2009) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.08.001 · Cited by 542
Matalanis, A., Jones, O. G., & McClements, D. J. (2011) · Food Hydrocolloids · doi:10.1016/j.foodhyd.2011.04.014 · Cited by 530
Mixing in microfluidic devices and enhancement methods
Ward, K., & Fan, Z. H. (2015) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/25/9/094001 · Cited by 453
Multiphase flow microfluidics for the production of single or multiple emulsions for drug delivery
Zhao, C.-X. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.05.009 · Cited by 451
Nanoparticle synthesis in microreactors
Zhao, C.-X., He, L., Qiao, S. Z., & Middelberg, A. P. J. (2011) · Chemical Engineering Science · doi:10.1016/j.ces.2010.08.039 · Cited by 430
Dripping and jetting in microfluidic multiphase flows applied to particle and fibre synthesis
Nunes, J. K., Tsai, S. S. H., Wan, J., & Stone, H. A. (2013) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/46/11/114002 · Cited by 406
Industrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.017 · Cited by 313
Functional Biopolymer Particles: Design, Fabrication, and Applications
Jones, O. G., & McClements, D. J. (2010) · Comprehensive Reviews in Food Science and Food Safety · doi:10.1111/j.1541-4337.2010.00118.x · Cited by 300
Wang, J., Wang, J., & Han, J. (2011) · Small · doi:10.1002/smll.201001913 · Cited by 293
Microfluidic generation of microgels from synthetic and natural polymers
Tumarkin, E., & Kumacheva, E. (2009) · Chemical Society Reviews · doi:10.1039/b809915b · Cited by 275
Patterning alginate hydrogels using light-directed release of caged calcium in a microfluidic device
Chueh, B.-H., Zheng, Y., Torisawa, Y.-S., Hsiao, A. Y., Ge, C., Hsiong, S., Huebsch, N., Franceschi, R., Mooney, D. J., & Takayama, S. (2010) · Biomedical Microdevices · doi:10.1007/s10544-009-9369-6 · Cited by 82
Metadata
- Authors
- Liu, K., Ding, H.-J., Liu, J., Chen, Y., & Zhao, X.-Z.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-09-22
- Volume
- 22
- Issue
- 22
- Pages
- 9453-9457
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W1968496263
- Cited by
- 223
- References
- 0
- FWCI
- 9.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.