CoChat

Highly Sensitive Detection of Target ssDNA Based on SERS Liquid Chip Using Suspended Magnetic Nanospheres as Capturing Substrates

Li, Ju-Mei, Ma, Wan-Fu, You, Li-Jun, Guo, Jia, Hu, Jun, Wang, Chang-Chun · 2013 · Langmuir
Cited by 46

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

A new approach for sensitive detection of a specific ssDNA (single-stranded DNA) sequence based on the surface enhanced Raman spectroscopy (SERS) liquid chip is demonstrated. In this method, the probe DNA (targeting to one part of target ssDNA) was attached to the nano-SERS-tags (poly(styrene-co-acrylic acid)/(silver nanoparticles)/silica composite nanospheres), and the capture DNA (targeting to the other part of target ssDNA) was attached to the Fe3O4/poly(acrylic acid) core/shell nanospheres. The nano-SERS-tags with probe DNA were first allowed to undergo hybridization with the target ssDNA in solution to achieve the best efficiency. Subsequently, the magnetic composite nanospheres with capture DNA were added as the capturing substrates of the target ssDNA combined with the nano-SERS-tags. Upon attraction with an external magnet, the nanospheres (including the nano-SERS-tags) were deposited together due to the hybridization, and the deposit sediment was then analyzed by SERS. Quantitative detection of target ssDNA was achieved based on the well-defined linear correlation between the SERS signal intensity and the target ssDNA quantity in the range of 10 nM to 10 pM, and the limit of detection was approximately 10 pM. Multiplexed detection of up to three different ssDNA targets in one sample was demonstrated using three different types of nano-SERS-tags under a single excitation laser. The experimental results indicated that the liquid-phase DNA sequencing method, thus named the SERS liquid chip (SLC) method, holds significant promises for specific detection of trace targets of organisms.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/la4006828

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 46

Metadata

Authors
Li, J.-M., Ma, W.-F., You, L.-J., Guo, J., Hu, J., & Wang, C.-C.
Venue
Langmuir
Published
2013-05-09
Volume
29
Issue
20
Pages
6147-6155
ISSN
  • 0743-7463 (ISSN-L)
  • 1520-5827
OpenAlex
W1992140499
Cited by
46
References
1
FWCI
3.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Highly Sensitive Detection of Target ssDNA Based on SERS Liquid Chip Using Suspended Magnetic Nanospheres as Capturing Substrates. https://app.cochat.ai/papers/10.1021/la4006828
The paper
Li, J.-M., Ma, W.-F., You, L.-J., Guo, J., Hu, J., & Wang, C.-C. (2013). Highly Sensitive Detection of Target ssDNA Based on SERS Liquid Chip Using Suspended Magnetic Nanospheres as Capturing Substrates. Langmuir. https://doi.org/10.1021/la4006828

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.