Generation of Stable Complex Gradients Across Two-Dimensional Surfaces and Three-Dimensional Gels
The DOI matches its Crossref record.
Abstract
Many chemical and biological processes are dependent on molecular gradients. We describe a new microfluidic approach that can be used to produce spatiotemporal gradients across two-dimensional surfaces and three-dimensional gels under flow-free conditions. Free diffusion between dynamically replenished flow channels acting as a sink and source is utilized to give rise to stable steady-state gradient profiles. The gradient profile is dictated by the engineered design of the device's gradient-generating region. Different designs can yield both linear and non-linear gradients of varying profiles. More complex gradients can be made by juxtaposing different designs within a single gradient-generating region. By fabricating an array of designs along the gradient-generating region, different gradient profiles can be generated simultaneously, allowing for parallel analysis. Additionally, simple methods of localizing gels into microdevices are demonstrated. The device was characterized by experimentally obtained gradient profiles of fluorescent molecules that corroborated closely with a simulated finite element model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biomolecular gradients in cell culture systems
Keenan, T. M., & Folch, A. (2008) · Lab Chip · doi:10.1039/b711887b · Cited by 596
Engineering microscale cellular niches for three-dimensional multicellular co-cultures
Huang, C. P., Lu, J., Seon, H., Lee, A. P., Flanagan, L. A., Kim, H.-Y., Putnam, A. J., & Jeon, N. L. (2009) · Lab on a Chip · doi:10.1039/b818401a · Cited by 384
Self-citationBiological applications of microfluidic gradient devices
Kim, S., Kim, H. J., & Jeon, N. L. (2010) · Integrative Biology · doi:10.1039/c0ib00055h · Cited by 366
Self-citationMicrofluidic tools for cell biological research
Velve-Casquillas, G., Le Berre, M., Piel, M., & Tran, P. T. (2010) · Nano Today · doi:10.1016/j.nantod.2009.12.001 · Cited by 359
Microfluidic techniques for development of 3D vascularized tissue
Hasan, A., Paul, A., Vrana, N. E., Zhao, X., Memic, A., Hwang, Y.-S., Dokmeci, M. R., & Khademhosseini, A. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.04.091 · Cited by 282
“The merger of hydrogels and microfabrication techniques has further led to the development of microfluidic platforms[14] that offer precise control over various aspects of the cellular microenvironment [15] including fluid flow [16, 17], chemical gradients [18, 19], localized extracellular matrix (ECM) [20–23] as well…”
Concentration gradient generation methods based on microfluidic systems
Wang, X., Liu, Z., & Pang, Y. (2017) · RSC Advances · doi:10.1039/c7ra04494a · Cited by 219
Microfluidics within a well: an injection-molded plastic array 3D culture platform
Lee, Y., Choi, J. W., Yu, J., Park, D., Ha, J., Son, K., Lee, S., Chung, M., Kim, H.-Y., & Jeon, N. L. (2018) · Lab on a Chip · doi:10.1039/c8lc00336j · Cited by 99
Self-citationSimultaneous or Sequential Orthogonal Gradient Formation in a 3D Cell Culture Microfluidic Platform
Uzel, S. G. M., Amadi, O. C., Pearl, T. M., Lee, R. T., So, P. T. C., & Kamm, R. D. (2016) · Small · doi:10.1002/smll.201501905 · Cited by 100
Shin, M. K., Kim, S. K., & Jung, H. (2011) · Lab on a Chip · doi:10.1039/c1lc20671k · Cited by 94
Metadata
- Authors
- Mosadegh, B., Huang, C., Park, J. W., Shin, H. S., Chung, B. G., Hwang, S.-K., Lee, K.-H., Kim, H. J., Brody, J., & Jeon, N. L.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-10-01
- Volume
- 23
- Issue
- 22
- Pages
- 10910-10912
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2051980827
- Cited by
- 109
- References
- 0
- FWCI
- 6.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.