Integration of intra- and extravasation in one cell-based microfluidic chip for the study of cancer metastasis
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Most studies of cancer metastasis focus on cancer cell invasion utilizing adhesion assays that are performed independently, and are thus limited in their ability to mimic complex cancer metastasis on a chip. Here we report the development of an integrated cell-based microfluidic chip for intra- and extravasation that combines two assays on one chip for the study of the complex cascade of cancer metastasis. This device consists of two parts; one is an intravasation chamber for the three-dimensional (3-D) culture of cancer cells using a Matrigel matrix, and the other is an extravasation chamber for the detection of metastasized cancer cells by adhesion molecules expressed by epithelial cells. In this novel system, the intravasation and extravasation processes of cancer metastasis can be studied simultaneously using four screw valves. Metastatic LOVO and non-metastatic SW480 cells were used in this study, and the invasion of LOVOs was found to be higher compared to SW480. In contrast, invasion of cells treated with metalloproteinase (MMP) inhibitors decreased within the intravasation chamber. Degraded cancer cells from the intravasation chamber were detected within the extravasation chamber under physiological conditions of shear stress, and differences in binding efficiency were also detected when CA19-9 antibody, an inhibitor of cancer cell adhesion, was used to treat degraded cancer cells. Our results support the potential usefulness of this new 3D cell-based microfluidic system as a drug screening tool to select targets for the development of new drugs and to verify their effectiveness.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Microfluidic assays have been designed to replicate certain aspects of several of these steps, such as EMT[13, 14], cancer cell invasion and adhesion[15–17], and intra-[18, 19] and extravasation[17, 20– 22] (see Text Box 3).”
From Microfluidics: A New Tool for Modeling Cancer–Immune Interactions (2016) · cites this paper as [16]
Citations
Cites
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
Metastasis: from dissemination to organ-specific colonization
Nguyen, D. X., Bos, P. D., & Massagué, J. (2009) · Nature Reviews Cancer · doi:10.1038/nrc2622 · Cited by 2,649
Zaman, M. H., Trapani, L. M., Sieminski, A. L., MacKellar, D., Gong, H., Kamm, R. D., Wells, A., Lauffenburger, D. A., & Matsudaira, P. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0604460103 · Cited by 1,160
Matrix metalloproteinases: multifunctional contributors to tumor progression
McCawley, L. J., & Matrisian, L. M. (2000) · Molecular Medicine Today · doi:10.1016/s1357-4310(00)01686-5 · Cited by 643
General mechanisms of metastasis
Woodhouse, E. C., Chuaqui, R. F., & Liotta, L. A. (1997) · Cancer · doi:10.1002/(sici)1097-0142(19971015)80:8+<1529::aid-cncr2>3.3.co;2-# · Cited by 609
General mechanisms of metastasis
Woodhouse, E. C., Chuaqui, R. F., & Liotta, L. A. (1997) · Cancer · doi:10.1002/(sici)1097-0142(19971015)80:8+<1529::aid-cncr2>3.0.co;2-f · Cited by 581
Cell migration into scaffolds under co-culture conditions in a microfluidic platform
Chung, S., Sudo, R., Mack, P. J., Wan, C.-R., Vickerman, V., & Kamm, R. D. (2009) · Lab Chip · doi:10.1039/b807585a · Cited by 519
The role of gelatinases in colorectal cancer progression and metastasis
Mook, O. R. F., Frederiks, W. M., & Van Noorden, C. J. F. (2004) · Biochimica et Biophysica Acta (BBA) - Reviews on Cancer · doi:10.1016/j.bbcan.2004.09.006 · Cited by 511
Critical determinants of metastasis
Fidler, I. J. (2002) · Seminars in Cancer Biology · doi:10.1006/scbi.2001.0416 · Cited by 413
Microfluidic Shear Devices for Quantitative Analysis of Cell Adhesion
Lu, H., Koo, L. Y., Wang, W. M., Lauffenburger, D. A., Griffith, L. G., & Jensen, K. F. (2004) · Analytical Chemistry · doi:10.1021/ac049837t · Cited by 405
Research works printed but not linked: 2
- Chakravorty, 2006, Biorheology, 43, 71
- Sul, 1995, Journal of Korean cancer association, 27, 209
Cited by
Biofabrication: A Guide to Technology and Terminology
Moroni, L., Boland, T., Burdick, J. A., De Maria, C., Derby, B., Forgacs, G., Groll, J., Li, Q., Malda, J., Mironov, V. A., et al. (2018) · Trends in Biotechnology · doi:10.1016/j.tibtech.2017.10.015 · Cited by 636
A microfluidic 3D in vitro model for specificity of breast cancer metastasis to bone
Bersini, S., Jeon, J. S., Dubini, G., Arrigoni, C., Chung, S., Charest, J. L., Moretti, M., & Kamm, R. D. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2013.11.050 · Cited by 534
Chen, M. B., Whisler, J. A., Fröse, J., Yu, C., Shin, Y., & Kamm, R. D. (2017) · Nature Protocols · doi:10.1038/nprot.2017.018 · Cited by 385
Chiang, S. P. H., Cabrera, R. M., & Segall, J. E. (2016) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00238.2015 · Cited by 311
Gut-on-a-chip: Current progress and future opportunities
Ashammakhi, N., Nasiri, R., Barros, N. R. D., Tebon, P., Thakor, J., Goudie, M., Shamloo, A., Martin, M. G., & Khademhosseini, A. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.120196 · Cited by 235
Metadata
- Authors
- Shin, M. K., Kim, S. K., & Jung, H.
- Affiliations
- Yonsei University (KR)
- Corresponding author
- Jung, Hyungil
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 11
- Issue
- 22
- Pages
- 3880
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2164059729
- Cited by
- 94
- References
- 36
- Citations by year
- 2026: 7 · 2025: 5 · 2024: 5 · 2023: 4 · 2022: 10 · 2021: 3 · 2020: 10 · 2019: 7 · 2018: 7 · 2017: 7 · 2016: 6 · 2015: 6 · 2014: 9 · 2013: 7 · 2012: 1
- FWCI
- 3.21
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Keywords
- metastasis, intravasation, extravasation, microfluidics, 3D cell culture, Matrigel, cell invasion, metalloproteinase inhibitors, tumor cell adhesion, shear stress, LoVo cells, SW480 cells, drug screening
- MeSH terms
- Cell Adhesion, Cell Separation, Cell Survival, Colonic Neoplasms, Humans, Neoplasm Invasiveness, Neoplasm Metastasis, Stress, Mechanical, Cell Adhesion Molecules, Gene Expression Regulation, Neoplastic, Systems Integration, Cell Line, Tumor, Microfluidic Analytical Techniques, Human Umbilical Vein Endothelial Cells
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Integration of intra- and extravasation in one cell-based microfluidic chip for the study of cancer metastasis. https://app.cochat.ai/papers/10.1039/c1lc20671k
- The paper
- Shin, M. K., Kim, S. K., & Jung, H. (2011). Integration of intra- and extravasation in one cell-based microfluidic chip for the study of cancer metastasis. Lab on a Chip. https://doi.org/10.1039/c1lc20671k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.