An in-situ hot stage for temperature-dependent tapping-mode™ atomic force microscopy
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Tapping-mode atomic force microscopy (TM-AFM) is a widely used method for the study of the nanometer scale morphology of soft materials such as biological samples and polymers. Many of these materials have structures and properties which are a sensitive function of temperature even below 100 °C making the control of temperature in such an instrument quite valuable. This paper describes the construction of a heater for a commercial TM-AFM which can reach surface temperatures as high as 100 °C. Temperature variations affect many experimental parameters in an atomic force microscope, and to compare images collected at different temperatures it is critical to evaluate these instrumental effects. In particular, the cantilever resonance frequency decreases as samples become hot; this effect is easily corrected by frequently resetting the drive frequency at high temperatures. As an example of the utility of this technique images of the nanoscale changes that occur prior to the bulk melting of paraffin crystals are presented.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Phase imaging and stiffness in tapping-mode atomic force microscopy
Magonov, S. N., Elings, V., & Whangbo, M.-H. (1997) · Surface Science · doi:10.1016/s0039-6028(96)01591-9 · Cited by 1,020
From Molecules to Cells: Imaging Soft Samples with the Atomic Force Microscope
Radmacher, M., Tillmann, R. W., Fritz, M., & Gaub, H. E. (1992) · Science · doi:10.1126/science.1411505 · Cited by 900
Rotator phases of the normal alkanes: An x-ray scattering study
Sirota, E. B., King, H. E., Singer, D. M., & Shao, H. H. (1993) · The Journal of Chemical Physics · doi:10.1063/1.464874 · Cited by 448
CHARACTERIZATION OF POLYMER SURFACES WITH ATOMIC FORCE MICROSCOPY
Magonov, S. N., & Reneker, D. H. (1997) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.27.1.175 · Cited by 444
Biological atomic force microscopy: what is achieved and what is needed
Shao, Z., Mou, J., Czajkowsky, D. M., Yang, J., & Yuan, J.-Y. (1996) · Advances in Physics · doi:10.1080/00018739600101467 · Cited by 325
Bar, G., Thomann, Y., Brandsch, R., Cantow, H.-J., & Whangbo, M.-H. (1997) · Langmuir · doi:10.1021/la970091m · Cited by 324
Burnham, N. A., Behrend, O. P., Oulevey, F., Gremaud, G., Gallo, P.-J., Gourdon, D., Dupas, E., Kulik, A. J., Pollock, H. M., & Briggs, G. A. D. (1997) · Nanotechnology · doi:10.1088/0957-4484/8/2/004 · Cited by 265
Anczykowski, B., Krüger, D., Babcock, K. L., & Fuchs, H. (1996) · Ultramicroscopy · doi:10.1016/s0304-3991(97)00002-8 · Cited by 165
Brandsch, R., Bar, G., & Whangbo, M.-H. (1997) · Langmuir · doi:10.1021/la970822i · Cited by 161
Research works printed but not linked: 3
- 1993, Surf. Sci., 290, L688
- 1995, Nanotechnology, 8, 40
- 1997, Ann. Phys. (Leipzig), 6, 341
Cited by
Palacios, J. K., Zhang, H., Zhang, B., Hadjichristidis, N., & Müller, A. J. (2020) · Polymer · doi:10.1016/j.polymer.2020.122863 · Cited by 11
Metadata
- Authors
- Prilliman, S. G., Kavanagh, A. M., Scher, E. C., Robertson, S. T., Hwang, K. S., & Colvin, V. L.
- Affiliations
- Rice University (US)
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1998-09-01
- Volume
- 69
- Issue
- 9
- Pages
- 3245-3250
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2010137156
- Cited by
- 19
- References
- 28
- Citations by year
- 2020: 2 · 2018: 1 · 2016: 1 · 2015: 1 · 2013: 1 · 2012: 1
- FWCI
- 0.73
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Review of Scientific Instruments (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Nanofabrication and Lithography Techniques
- Keywords
- tapping mode atomic force microscopy, in situ heating, cantilever resonance frequency, soft materials, polymers, biological specimen
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An in-situ hot stage for temperature-dependent tapping-mode™ atomic force microscopy. https://app.cochat.ai/papers/10.1063/1.1149090
- The paper
- Prilliman, S. G., Kavanagh, A. M., Scher, E. C., Robertson, S. T., Hwang, K. S., & Colvin, V. L. (1998). An in-situ hot stage for temperature-dependent tapping-mode™ atomic force microscopy. Review of Scientific Instruments. https://doi.org/10.1063/1.1149090
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.