The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Characterization of Porous Glasses: Simulation Models, Adsorption Isotherms, and the Brunauer−Emmett−Teller Analysis Method
Abstract
We have developed a realistic model for studying adsorption in porous glasses which reproduces the complex structure of these materials. The model porous material is generated by a quench molecular dynamics procedure which mimics the processes by which Vycor glass and controlled-pore glasses are produced. We examine this procedure and the resulting model materials by a variety of methods and find that they have porosities, pore sizes, and surface areas very similar to the real glasses. These simulated glasses have precisely known properties (surface area, pore size distribution, etc.), in contrast to experimental glasses; computer experiments on such model glasses can therefore be used to test new and existing experimental methods of characterization. We calculate the adsorption isotherms for a model of nitrogen adsorbing onto these materials and analyze these data using the BET isotherm. The BET monolayer density exhibits systematic variations with both the average pore size and the porosity of the model glasses, which can be partially explained by studying the variations of adsorption energies in the different systems. We have done similar calculations in a series of ideal planar and cylindrical pore systems with comparable surface micro-structure. We find that there is a systematic error involved in comparing the networked glasses to the ideal cylinders as is commonly done in the analysis of these materials. For glasses with large pores this error is negligible, but for very small pores it can be significant. We discuss the implications of these findings for other standard techniques of isotherm analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adsorption of Gases in Multimolecular Layers
Brunauer, S., Emmett, P. H., & Teller, E. (1938) · Journal of the American Chemical Society · doi:10.1021/ja01269a023 · Cited by 28,156
Analytical molecular surface calculation
Connolly, M. L. (1983) · Journal of Applied Crystallography · doi:10.1107/s0021889883010985 · Cited by 2,508
Late stages of spinodal decomposition in binary mixtures
Siggia, E. D. (1979) · Physical Review A · doi:10.1103/physreva.20.595 · Cited by 1,294
Pore size distribution analysis of microporous carbons: a density functional theory approach
Lastoskie, C., Gubbins, K. E., & Quirke, N. (1993) · The Journal of Physical Chemistry · doi:10.1021/j100120a035 · Cited by 1,219
Self-citationEquation of state for the Lennard-Jones fluid
Nicolas, J. J., Gubbins, K. E., Streett, W. B., & Tildesley, D. J. (1979) · Molecular Physics · doi:10.1080/00268977900101051 · Cited by 829
Self-citationComputation of molecular volume
Connolly, M. L. (1985) · Journal of the American Chemical Society · doi:10.1021/ja00291a006 · Cited by 597
Fluids in narrow pores: Adsorption, capillary condensation, and critical points
Evans, R., Marconi, U. M. B., & Tarazona, P. (1986) · The Journal of Chemical Physics · doi:10.1063/1.450352 · Cited by 531
Grand canonical ensemble Monte Carlo for a Lennard-Jones fluid
Adams, D. J. (1975) · Molecular Physics · doi:10.1080/00268977500100221 · Cited by 519
Levitz, P., Ehret, G., Sinha, S. K., & Drake, J. M. (1991) · The Journal of Chemical Physics · doi:10.1063/1.461583 · Cited by 371
Pore size heterogeneity and the carbon slit pore: a density functional theory model
Lastoskie, C., Gubbins, K. E., & Quirke, N. (1993) · Langmuir · doi:10.1021/la00034a032 · Cited by 345
Self-citation
Cited by
Phase separation in confined systems
Gelb, L. D., Gubbins, K. E., Radhakrishnan, R., & Sliwinska-Bartkowiak, M. (1999) · Reports on Progress in Physics · doi:10.1088/0034-4885/62/12/201 · Cited by 1,568
Self-citationPhysisorption Hysteresis Loops and the Characterization of Nanoporous Materials
Sing, K. S. W., & Williams, R. T. (2004) · Adsorption Science & Technology · doi:10.1260/0263617053499032 · Cited by 1,266
Finlayson-Pitts, B. J., Wingen, L. M., Sumner, A. L., Syomin, D., & Ramazan, K. A. (2003) · Physical Chemistry Chemical Physics · doi:10.1039/b208564j · Cited by 691
Sarkisov, L., & Harrison, A. (2011) · Molecular Simulation · doi:10.1080/08927022.2011.592832 · Cited by 658
Thommes, M., Smarsly, B., Groenewolt, M., Ravikovitch, P. I., & Neimark, A. V. (2006) · Langmuir · doi:10.1021/la051686h · Cited by 589
Pore Size Distributions in Porous Glasses: A Computer Simulation Study
Gelb, L. D., & Gubbins, K. E. (1999) · Langmuir · doi:10.1021/la9808418 · Cited by 516
Self-citationRavikovitch, P. I., & Neimark, A. V. (2002) · Langmuir · doi:10.1021/la026140z · Cited by 512
Characterization of nanoporous materials from adsorption and desorption isotherms
Ravikovitch, P. I., & Neimark, A. V. (2001) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/s0927-7757(01)00614-8 · Cited by 433
Manzano, H., Moeini, S., Marinelli, F., van Duin, A. C. T., Ulm, F.-J., & Pellenq, R. J.-M. (2012) · Journal of the American Chemical Society · doi:10.1021/ja209152n · Cited by 347
Bae, Y.-S., Yazaydın, A. Ö., & Snurr, R. Q. (2010) · Langmuir · doi:10.1021/la100449z · Cited by 342
Porous glasses in the 21st century––a short review
Enke, D., Janowski, F., & Schwieger, W. (2003) · Microporous and Mesoporous Materials · doi:10.1016/s1387-1811(03)00329-9 · Cited by 282
Adsorption, intrusion and freezing in porous silica: the view from the nanoscale
Coasne, B., Galarneau, A., Pellenq, R. J. M., & Di Renzo, F. (2013) · Chemical Society Reviews · doi:10.1039/c2cs35384a · Cited by 263
Molecular simulation of water confined in nanoporous silica
Bonnaud, P. A., Coasne, B., & Pellenq, R. J.-M. (2010) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/22/28/284110 · Cited by 182
Metadata
- Authors
- Gelb, L. D., & Gubbins, K. E.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-03-20
- Volume
- 14
- Issue
- 8
- Pages
- 2097-2111
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2010137158
- Cited by
- 432
- References
- 24
- FWCI
- 10.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.