The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Synthesis and Characterization of Photopolymerized Multifunctional Hydrogels: Water-Soluble Poly(Vinyl Alcohol) and Chondroitin Sulfate Macromers for Chondrocyte Encapsulation
Abstract
To design a carrier for chondrocytes that emulates the critical aspects of native cartilage tissue, hydrogels were formulated from a synthetic component based on poly(vinyl alcohol) (PVA) and from a natural component, negatively charged chondroitin sulfate (ChSA, a main component of proteoglycans). The synthesis of photoreactive and crosslinkable macromers based on PVA and ChSA is described in detail. A range of macroscopic hydrogel properties was obtained by varying the macromer molecular weight, concentration, and functionality prior to photoinitiated polymerization. Depending on the formulation, the PVA homopolymer gels had compressive moduli ( K ) ranging from 5 to 1680 kPa with equilibrium mass swelling ratios ( q ) of 2.4 to 15. Similar variations in pure ChSA gels produced networks with K 's from 10 to 2600 kPa and q 's from 5.9 to 27.5. Copolymer networks containing both ChSA and PVA had increased mechanics and increased swelling as compared to the homopolymer gels. An additional benefit to incorporating ChSA was the creation of enzymatically degradable gels. By use of chondroitinase ABC, the degradation kinetics of various homo- and copolymer networks were investigated. Finally, preliminary histological results indicate that these copolymer gels can support chondrogenesis of photoencapsulated cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bryant, S. J., & Anseth, K. S. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1217 · Cited by 845
Self-citation
Cited by
Polymeric Scaffolds in Tissue Engineering Application: A Review
Dhandayuthapani, B., Yoshida, Y., Maekawa, T., & Kumar, D. S. (2011) · International Journal of Polymer Science · doi:10.1155/2011/290602 · Cited by 1,773
Design properties of hydrogel tissue-engineering scaffolds
Zhu, J., & Marchant, R. E. (2011) · Expert Review of Medical Devices · doi:10.1586/erd.11.27 · Cited by 1,430
Cell Encapsulation in Biodegradable Hydrogels for Tissue Engineering Applications
Nicodemus, G. D., & Bryant, S. J. (2008) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2007.0332 · Cited by 1,239
Self-citation3D printing of hydrogels: Rational design strategies and emerging biomedical applications
Li, J., Wu, C., Chu, P. K., & Gelinsky, M. (2020) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2020.100543 · Cited by 862
Chung, C., & Burdick, J. A. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.08.027 · Cited by 760
Metadata
- Authors
- Bryant, S. J., Davis-Arehart, K. A., Luo, N., Shoemaker, R. K., Arthur, J. A., & Anseth, K. S.
- Venue
- Macromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-08-07
- Volume
- 37
- Issue
- 18
- Pages
- 6726-6733
- ISSN
- 0024-9297 (ISSN-L)
- 1520-5835
- OpenAlex
- W2070050615
- Cited by
- 183
- References
- 1
- FWCI
- 2.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.