Thermally Responsive Swelling Properties of Polyacrylamide/Poly(acrylic acid) Interpenetrating Polymer Network Nanoparticles
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Interpenetrating polymer network (IPN), random copolymer, and homopolymer nanoparticles of acrylamide and acrylic acid were prepared using an inverse emulsion polymerization technique. Differential scanning calorimetry and Fourier-transform infrared spectroscopy were used to examine the molecular structure of the prepared polymeric nanoparticles. The spherical morphology and size (∼250 nm diameter) of the nanoparticles was confirmed using scanning electron microscopy. Dynamic light scattering was used to determine the monodispersity of the particle size distribution and examine the thermally responsive swelling properties of the polymeric nanoparticle structures. Of the particle systems studied, only the IPN nanoparticles exhibited a unique, rapid sigmoidal swelling transition with temperature. These systems also achieved a much larger relative swelling volume compared to random copolymer and homopolymer particles comprised of acrylamide and acrylic acid. Increased cross-linker density resulted in an overall decrease in the maximum relative swelling volume that was obtained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermosensitive sol-gel reversible hydrogels
Jeong, B., Kim, S. W., & Bae, Y. H. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00242-3 · Cited by 1,478
Stimuli-sensitive hydrogels: ideal carriers for chronobiology and chronotherapy
Peppas, N. A., & Leobandung, W. (2004) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856204322793539 · Cited by 112
Self-citation
Cited by
The development of microgels/nanogels for drug delivery applications
Oh, J. K., Drumright, R., Siegwart, D. J., & Matyjaszewski, K. (2008) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.01.002 · Cited by 1,598
Stimulus-responsive hydrogels: theory, modern advances, and applications
Koetting, M. C., Peters, J. T., Steichen, S. D., & Peppas, N. A. (2015) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2015.04.001 · Cited by 1,191
Self-citationRizwan, M., Yahya, R., Hassan, A., Yar, M., Azzahari, A., Selvanathan, V., Sonsudin, F., & Abouloula, C. (2017) · Polymers · doi:10.3390/polym9040137 · Cited by 844
“The UCST response in poly(acrylic acid) and poly(acrylamide) is primarily due to the presence of secondary hydrogen bonding which dominates at low temperature and keeps the hydrogel matrix shrunk whereas, with increasing temperature, hydrogen bonds weaken and the hydrophilic ends become exposed leading to the phenomen…”
BackgroundWeak Hydrogen Bonding Enables Hard, Strong, Tough, and Elastic Hydrogels
Hu, X., Vatankhah‐Varnoosfaderani, M., Zhou, J., Li, Q., & Sheiko, S. S. (2015) · Advanced Materials · doi:10.1002/adma.201503724 · Cited by 596
Thermo-responsive polymers and their application as smart biomaterials
Kim, Y.-J., & Matsunaga, Y. T. (2017) · Journal of Materials Chemistry B · doi:10.1039/c7tb00157f · Cited by 568
Metadata
- Authors
- Owens, D. E., Jian, Y., Fang, J. E., Slaughter, B. V., Chen, Y.-H., & Peppas, N. A.
- Venue
- Macromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-08-29
- Volume
- 40
- Issue
- 20
- Pages
- 7306-7310
- ISSN
- 0024-9297 (ISSN-L)
- 1520-5835
- OpenAlex
- W2041320896
- Cited by
- 124
- References
- 2
- FWCI
- 3.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.