Biodistribution, Clearance, and Biocompatibility of Iron Oxide Magnetic Nanoparticles in Rats
Abstract
It is essential to determine the biodistribution, clearance, and biocompatibility of magnetic nanoparticles (MNPs) for in vivo biomedical applications to ensure their safe clinical use. We have studied these aspects with our novel iron oxide MNP formulation, which can be used as a magnetic resonance imaging (MRI) agent and a drug carrier system. Changes in serum and tissue iron levels were analyzed over 3 weeks after intravenous administration of MNPs to rats. Serum alanine aminotransferase (ALT), aspartate aminotransferase (AST), alkaline phosphatase (AKP) levels, and total iron-binding capacity (TIBC) were also measured with time to assess the effect of MNPs on liver function. Selected tissues were also analyzed for oxidative stress and studied histologically to determine biocompatibility of MNPs. Serum iron levels gradually increased for up to 1 week but levels slowly declined thereafter. Biodistribution of iron in various body tissues changed with time but greater fraction of the injected iron localized in the liver and spleen than in the brain, heart, kidney, and lung. Magnetization measurements of the liver and spleen samples showed a steady decrease over 3 weeks, suggesting particle degradation. Serum showed a transient increase in ALT, AST, AKP levels, and TIBC over a period of 6-24 h following MNP injection. The increase in oxidative stress was tissue dependent, reaching a peak at approximately 3 days and then slowly declining thereafter. Histological analyses of liver, spleen, and kidney samples collected at 1 and 7 days showed no apparent abnormal changes. In conclusion, our MNPs did not cause long-term changes in the liver enzyme levels or induce oxidative stress and thus can be safely used for drug delivery and imaging applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sources and role of iron in lipid peroxidation
Minotti, G. (1993) · Chemical Research in Toxicology · doi:10.1021/tx00032a001 · Cited by 154
Cited by
Longmire, M., Choyke, P. L., & Kobayashi, H. (2008) · Nanomedicine · doi:10.2217/17435889.3.5.703 · Cited by 2,149
Reddy, L. H., Arias, J. L., Nicolas, J., & Couvreur, P. (2012) · Chemical Reviews · doi:10.1021/cr300068p · Cited by 2,010
Synthesis, characterization, applications, and challenges of iron oxide nanoparticles
Ali, A., Zafar, H., Zia, M., ul Haq, I., Phull, A. R., Ali, J. S., & Hussain, A. (2016) · Nanotechnology, Science and Applications · doi:10.2147/nsa.s99986 · Cited by 1,591
Nanoparticles as drug delivery systems
Wilczewska, A. Z., Niemirowicz, K., Markiewicz, K. H., & Car, H. (2012) · Pharmacological Reports · doi:10.1016/s1734-1140(12)70901-5 · Cited by 1,445
Superparamagnetic iron oxide nanoparticles: magnetic nanoplatforms as drug carriers
Wahajuddin, & Arora (2012) · International Journal of Nanomedicine · doi:10.2147/ijn.s30320 · Cited by 1,117
Metadata
- Authors
- Jain, T. K., Reddy, M. K., Morales, M. A., Leslie-Pelecky, D. L., & Labhasetwar, V.
- Venue
- Molecular Pharmaceutics
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-01-25
- Volume
- 5
- Issue
- 2
- Pages
- 316-327
- ISSN
- 1543-8384 (ISSN-L)
- 1543-8392
- OpenAlex
- W2047855476
- Cited by
- 705
- References
- 1
- FWCI
- 26.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biodistribution, Clearance, and Biocompatibility of Iron Oxide Magnetic Nanoparticles in Rats. https://app.cochat.ai/papers/10.1021/mp7001285
- The paper
- Jain, T. K., Reddy, M. K., Morales, M. A., Leslie-Pelecky, D. L., & Labhasetwar, V. (2008). Biodistribution, Clearance, and Biocompatibility of Iron Oxide Magnetic Nanoparticles in Rats. Molecular Pharmaceutics. https://doi.org/10.1021/mp7001285
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.