The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Silicon Nanoribbons for Electrical Detection of Biomolecules
Abstract
Direct electrical detection of biomolecules at high sensitivity has recently been demonstrated using semiconductor nanowires. Here we demonstrate that semiconductor nanoribbons, in this case, a thin sheet of silicon on an oxidized silicon substrate, can approach the same sensitivity extending below the picomolar concentration regime in the biotin/streptavidin case. This corresponds to less than approximately 20 analyte molecules bound to receptors on the nanoribbon surface. The micrometer-size lateral dimensions of the nanoribbon enable optical lithography to be used, resulting in a simple and high-yield fabrication process. Electrical characterization of the nanoribbons is complemented by computer simulations showing enhanced sensitivity for thin ribbons. Finally, we demonstrate that the device can be operated both in inversion as well as in accumulation mode and the measured differences in detection sensitivity are explained in terms of the distance between the channel and the receptor coated surface with respect to the Debye screening length. The nanoribbon approach opens up for large scale CMOS fabrication of highly sensitive biomolecule sensor chips for potential use in medicine and biotechnology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Label-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352
Importance of the Debye Screening Length on Nanowire Field Effect Transistor Sensors
Stern, E., Wagner, R., Sigworth, F. J., Breaker, R., Fahmy, T. M., & Reed, M. A. (2007) · Nano Letters · doi:10.1021/nl071792z · Cited by 806
Surface Charge Sensitivity of Silicon Nanowires: Size Dependence
Elfström, N., Juhasz, R., Sychugov, I., Engfeldt, T., Karlström, A. E., & Linnros, J. (2007) · Nano Letters · doi:10.1021/nl0709017 · Cited by 275
Self-citationChemical sensing with ZnO nanowire field-effect transistor
Fan, Z., & Lu, J. G. (2006) · IEEE Transactions On Nanotechnology · doi:10.1109/tnano.2006.877428 · Cited by 106
Cited by
Electrolyte-Gated Graphene Field-Effect Transistors for Detecting pH and Protein Adsorption
Ohno, Y., Maehashi, K., Yamashiro, Y., & Matsumoto, K. (2009) · Nano Letters · doi:10.1021/nl901596m · Cited by 833
Label-free biomarker detection from whole blood
Stern, E., Vacic, A., Rajan, N. K., Criscione, J. M., Park, J., Ilic, B. R., Mooney, D. J., Reed, M. A., & Fahmy, T. M. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2009.353 · Cited by 543
Duan, X., Li, Y., Rajan, N. K., Routenberg, D. A., Modis, Y., & Reed, M. A. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.82 · Cited by 366
Effect of Nanowire Number, Diameter, and Doping Density on Nano-FET Biosensor Sensitivity
Li, J., Zhang, Y., To, S., You, L., & Sun, Y. (2011) · ACS Nano · doi:10.1021/nn202182p · Cited by 138
Optimization of the Sensitivity of FET-Based Biosensors via Biasing and Surface Charge Engineering
Shoorideh, K., & Chui, C. O. (2012) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2012.2214221 · Cited by 65
Metadata
- Authors
- Elfström, N., Karlström, A. E., & Linnros, J.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-02-12
- Volume
- 8
- Issue
- 3
- Pages
- 945-949
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2029236613
- Cited by
- 185
- References
- 4
- FWCI
- 13.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Silicon Nanoribbons for Electrical Detection of Biomolecules. https://app.cochat.ai/papers/10.1021/nl080094r
- The paper
- Elfström, N., Karlström, A. E., & Linnros, J. (2008). Silicon Nanoribbons for Electrical Detection of Biomolecules. Nano Letters. https://doi.org/10.1021/nl080094r
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.