The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Anti-CD4-targeted Gold Nanoparticles Induce Specific Contrast Enhancement of Peripheral Lymph Nodes in X-ray Computed Tomography of Live Mice
Abstract
Antibody-conjugated gold nanoparticles have been applied as a biologically targeted contrast agent in live mice for one of the most widely used medical imaging methods, X-ray computed tomography. Such nanoprobes directed toward the CD4 receptor lead to distinctly enhanced X-ray contrast of peripheral lymph nodes. This study demonstrates the general feasibility of biologically specific X-ray imaging in living animals and discusses basic requirements for the use of nanoparticles as a targeted X-ray contrast agent.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Renal clearance of quantum dots
Soo Choi, H., Liu, W., Misra, P., Tanaka, E., Zimmer, J. P., Itty Ipe, B., Bawendi, M. G., & Frangioni, J. V. (2007) · Nature Biotechnology · doi:10.1038/nbt1340 · Cited by 4,476
Noninvasive detection of macrophages using a nanoparticulate contrast agent for computed tomography
Hyafil, F., Cornily, J.-C., Feig, J. E., Gordon, R., Vucic, E., Amirbekian, V., Fisher, E. A., Fuster, V., Feldman, L. J., & Fayad, Z. A. (2007) · Nature Medicine · doi:10.1038/nm1571 · Cited by 467
Cited by
Khlebtsov, N., & Dykman, L. (2011) · Chem. Soc. Rev. · doi:10.1039/c0cs00018c · Cited by 1,584
X-ray-Computed Tomography Contrast Agents
Lusic, H., & Grinstaff, M. W. (2013) · Chemical Reviews · doi:10.1021/cr200358s · Cited by 1,108
Lee, N., Choi, S. H., & Hyeon, T. (2013) · Advanced Materials · doi:10.1002/adma.201300081 · Cited by 657
Polymeric nanostructured materials for biomedical applications
Tang, Z., He, C., Tian, H., Ding, J., Hsiao, B. S., Chu, B., & Chen, X. (2016) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2016.05.005 · Cited by 363
Nanoparticle contrast agents for computed tomography: a focus on micelles
Cormode, D. P., Naha, P. C., & Fayad, Z. A. (2014) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.1551 · Cited by 362
Gold Nanoparticles as Contrast Agents in x-ray Imaging and Computed Tomography
Cole, L. E., Ross, R. D., Tilley, J. M., Vargo-Gogola, T., & Roeder, R. K. (2015) · Nanomedicine · doi:10.2217/nnm.14.171 · Cited by 356
Ai, K., Liu, Y., Liu, J., Yuan, Q., He, Y., & Lu, L. (2011) · Advanced Materials · doi:10.1002/adma.201103289 · Cited by 349
Liu, Y., Ai, K., & Lu, L. (2012) · Accounts of Chemical Research · doi:10.1021/ar300150c · Cited by 345
Metadata
- Authors
- Eck, W., Nicholson, A. I., Zentgraf, H., Semmler, W., & Bartling, S.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-05-24
- Volume
- 10
- Issue
- 7
- Pages
- 2318-2322
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2069796930
- Cited by
- 163
- References
- 2
- FWCI
- 12.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.